Image Continuum CASA 6.1.1: Difference between revisions

From CASA Guides
Jump to navigationJump to search
Akepley (talk | contribs)
Tashton (talk | contribs)
 
(122 intermediate revisions by 5 users not shown)
Line 1: Line 1:
This guide should be used after completing '''[[Imaging_Prep | Prepare the data for Imaging]]'''. You should have created '''calibrated_final.ms''' prior to proceeding.
This guide should be used after completing '''[[Imaging_Prep | Prepare the data for Imaging]]'''. You should have created '''calibrated_final.ms''' prior to proceeding.
Commands for this guide can be found in scriptForImaging_template.py available on [https://github.com/aakepley/ALMAImagingScript github].
== Check CASA version ==
== Check CASA version ==


This template is for use in CASA versions 4.4 and greater. The following code checks the version of CASA and exits if it is less than 4.4.0. You can download the appropriate version of CASA from [https://casa.nrao.edu/casa_obtaining.shtml Obtaining CASA] . See [[Guide_NA_ImagingTemplate#Prepare for Imaging | Prepare for Imaging ]] section on the main page of this guide for more information.
This template is for use in CASA versions 6.1.1.15 and greater. The following code checks the version of CASA and exits if it is less than 6.1.1.15. You can download the appropriate version of CASA from [https://casa.nrao.edu/casa_obtaining.shtml Obtaining CASA] . See [[Guide_NA_ImagingTemplate#Prepare for Imaging | Prepare for Imaging ]] section on the main page of this guide for more information.


<source lang="python">
<source lang="python">
# in CASA
# in CASA
import re
import re
try:
    import casalith
except:
    print("Script requires CASA 6.0 or greater")


if casadef.casa_version < '4.4.0' :
if casalith.compare_version("<",[6,1,1,15]):
     sys.exit("Please use CASA version greater than or equal to 4.4.0 with this script")
     print("Please use CASA version greater than or equal to 6.1.1-15 with this script")
</source>
</source>


== Image Parameters ==
== Create an Averaged Continuum MS ==
 
[[File:Calibrated_final_Field0_Spw0.png|thumb|Figure 1: spw 0]]
Before imaging, you should set a few key parameters that you will use throughout the rest of the script.  
[[File:Calibrated_final_Field0_Spw3.png|thumb|Figure 2: Plots showing each spectral window for TW Hydra with channel vs amplitude. Spw 0 has a strong spectral line and spw 3 is a continuum only window.]]
Appropriate averaging of a measurement set can reduce overall data volume, making imaging faster with {{tclean}}.  Since the continuum image is formed by essentially summing the entire bandwidth, we can spectrally average the input measurement set prior to imaging without significantly affecting the final imaging results. Below, we outline a procedure to create a spectrally averaged measurement set for continuum imaging.  


Set the field id for the science target you are interested in imaging. Check the [https://almascience.nrao.edu/proposing/observing-tool ALMA Observing Tool] (OT) as well as the listobs file generated to find this information. If you are imaging a mosaic then you will have to select all the fields as field = ‘3~25’.  You can also set the field variable to the name of the source, as long as it matches the name in the listobs file. Do not leave the field parameter blank.
The first step is to identify which spectral windows (spws) you would like to include in the continuum. In general, you should include all spws with bandwidths greater than 250MHz to maximize the available continuum bandwidth. Once you have determined which spws you would like to use to form the continuum ms, set the contspw variable:


<source lang="python">
<source lang="python">
# in CASA
# in CASA
# update for your ms
finalvis='calibrated_final.ms' # This is your output ms from the data
field='0'
                              # preparation script.
</source>
# Set spws to be used to form continuum
 
contspws = '0,1,2,3'
Uncomment the imagermode that is relevant to your dataset. Set the phase center by field id or coordinates if you are imaging a mosaic. Check the spatial setup in the weblog (for pipeline calibrations) or qa2 report (for manual calibrations) to find the phase center. You should choose the central field for the phase center in order to get the best results.
 
If you are unsure which field to use for the phase center after looking at the weblog then you may use the following Analysis Utilities command:
 
<source lang="python">
au.pickCellSize(‘calibrated_final.ms',imsize=True).
</source>
 
This will return a four element array with that contains the calculated cell size, the X axis number of pixels, the Y axis number of pixels, and the field number that is most centered in the mosaic. You may use this as the phase center field id in your script.
 
Another method of finding the central field number is using the task [https://casaguides.nrao.edu/index.php/Plotmosaic au.plotmosaic](‘calibrated_final.ms’) within CASA. This method will produce a plot of all fields with their corresponding field numbers plotted on the sky. You can also set the phase center with the coordinates at the center of this plot.
 
<source lang="python">
# in CASA
# imagermode='csclean' # uncomment if single field
# imagermode='mosaic' # uncomment if mosaic or if combining one 7m and one 12m pointing.
# phasecenter=3 # uncomment and set to field number for phase
            # center. Note lack of ''.  Use the weblog to
            # determine which pointing to use. Remember that the
            # field ids for each pointing will be re-numbered
            # after your initial split. You can also specify the
            # phase center using coordinates, e.g.,
            # phasecenter='J2000 19h30m00 -40d00m00'
</source>
<figure id="Calibrated_final_AmpVsUVWave.png">
[[File:Calibrated_final_AmpVsUVWave.png|thumb|<caption>Amplitude versus UV wave for the calibrated_final.ms showing the maximum uv wave point for determining cell size.</caption>]]
</figure>
Next you will determine the cell size. Find the approximate beam size of your observation using the following equation:
 
<pre style="background-color: #E0FFFF;">
206265.0/(longest baseline in wavelengths) ~ Beam Size(arcseconds)
</pre>
 
To determine the longest baseline in wavelength use plotms with xaxis=’uvwave’ and yaxis=’amp’ on your ms file. Figure 1 shows an example of this plot. It is recommended you fit 5 to 8 cells per beam when imaging. Therefore you can find the cell size by dividing the Beam Size by at least 5, however it is always better to put more pixels across your beam than too few.
 
<pre style="background-color: #E0FFFF;">
Beam Size/5 ~ Cell Size(arc seconds)
</pre>
 
The next step is to determine the image size in pixels. There are two methods of doing this depending on if you are imaging one field or a mosaic.
 
If this is a single field, the image size can usually be approximated to be the same size as the primary beam of the telescope. The ALMA 12m primary beam in arcsec scales as 6300 / nu[GHz] and the ALMA 7m primary beam in arcsec scales as 10608 / nu[GHz], where nu[GHz] is the sky frequency. However, if there is significant point source and/or extended emission beyond the edges of your initial images, you should increase the imsize to incorporate more emission.
 
For mosaics, you can get the imsize from the spatial tab of the OT. The parameters "p length" and "q length" specify the dimensions of the mosaic. If you're imaging a mosaic, pad the imsize substantially to avoid artifacts. To know if you have padded enough you should, in your images, be able to see the edges of the outside fields being cut off.
<figure id="Antennae_Antennae_North.Cont.Dirty.image.png">
[[File:Antennae_Antennae_North.Cont.Dirty.image.png|thumb]]
</figure>
<figure id="Antennae_North.Cont.Dirty.smallIMSize.image.png">
[[File:Antennae_North.Cont.Dirty.smallIMSize.image.png|thumb|<caption>A mosaic of Antennae showing under padding and correctly padded images. For the correctly padded image you can see the edges of the primary beam field whereas the under padded does not cut off.
</caption>]]
</figure>
Note that the imsize parameter is in PIXELS, not arcsec, so you will need to divide the image size in arcsec by the pixel size to determine a value for imsize.
 
If you would like to check any of these calculations you may use the following command, [https://safe.nrao.edu/wiki/bin/view/ALMA/PickCellSize au.pickCellSize]('calibrated_final.ms', imsize=True), in CASA. This will return a four element array of the calculated cell size, the x axis imsize, the y axis imsize, and the central field id number.
<source lang="python">
# in CASA
cell='1arcsec' # cell size for imaging.
imsize = [128,128] # size of image in pixels.
</source>
 
When imaging you will need to set two specific velocity parameters called outframe and veltype. Outframe is the coordinate system used for the observation and can be found in the OT under field setup. A list of acceptable outframes that can be used in CASA can be found at https://help.almascience.org/index.php?/Knowledgebase/Article/View/86/0/what-are-the-frequency-reference-frames-in-casa. Note: heliocentric(hel) is deprecated in CASA. Use barycentric(bary) in this case.
 
You will also have to set the veltype for the {{clean}} command. This variable has only two options available, radio and optical. It is standard to leave this set to ‘radio’ in all projects regardless of the velocity frame used in the project.
 
<source lang="python">
# in CASA
outframe='bary' # velocity reference frame. See science goals.
veltype='radio' # velocity type.
</source>
</source>


The last four parameters that must be set are associated with how {{clean}} will weight and {{clean}} the data. Weighting determines how much influence data points in the UV plane have on the final image. There are several weighting schemes that can be used such as briggs, natural and uniform weighting.
The next step is to identify and flag the spectral lines in all spectral windows that you will use to make the continuum image. You will split and average the data with the spectral lines flagged so that your final spectrally averaged continuum ms only contains continuum emission. Two methods commonly used to identical spectral line emission are: 1) a channel vs. amplitude plot of the visibilities and 2) a dirty image of the cube.
 
* Natural: Natural weighting uses the same weights as that of the data weights when collected. This weighting scheme is the default in {{clean}} and gives low rms noise to the image but a poor angular resolution.  
 
* Uniform: Uniform weighting will give all points in the UV plane the same influence regardless of their weight. The sidelobes will be reduced because the uv-plane is filled more uniformly. This gives more weight to longer baselines so angular resolution is enhanced while sensitivity is degraded.
 
* Briggs and the Robust Parameter: This is the most common weighting used and gives a balance between the low rms of natural weighting while also giving the excellent angular resolution of uniform weighting. Briggs weighting will vary the weighting given to UV cells with the robust parameter. Setting this to 2 gives Natural weighting, -2 Uniform weighting, and a number in between a variance of the two. Refer to [http://www.atnf.csiro.au/people/tim.cornwell/research/danthesis.pdf Brigg's Thesis] for more information.


Currently, robust is set to 0.5 which gives a good compromise between natural and uniform weighting. You may find, after imaging, that you have to decrease the rms noise or angular resolution based on the desired performance requested in the proposal. Playing with the robust parameter can affect your final rms noise in the image and also the angular resolution.  
To use the first method, create a channel vs. amplitude plot using plotms. An example command is given below. You may wish to change the averaging and the uvrange to identify extended emission.  


The niter and threshold parameters affect when {{clean}} will stop the cleaning process. niter is the maximum number of iterations allowed and once this number has reached zero interactive cleaning will finish.  
Figures 1 and 2 show example plots of a spw with and without lines to flag. Figure 1 shows a clear line at channel 1700 whereas Figure 2 shows no line emission and just continuum.
Once a certain flux level, set by threshold, has been reached, {{clean}} will stop. This is by default set at 0.0mJy but may be increased to prevent cleaning too deeply into the thermal noise.


There are several methods to determine what to set threshold to if you desire to change it. One method is to make a {{clean}} mask by setting niter equal to zero, then inspecting the image produced using {{viewer}}. Select a box around an area of no emission to determine the rms noise of the image, which should be the approximate value of the threshold parameter. Follow the instructions located in the “Image the Spectral Line Data” section of [https://casaguides.nrao.edu/index.php?title=EVLA_Spectral_Line_Imaging_Analysis_IRC%2B10216 EVLA Spectral Line Imaging Analysis IRC+10216].
Warning: If you apply channel averaging greater than 1, the numbers displayed on the channel axis will represent the channel bin number, rather than the averaged channel.
If you plan on cleaning non-interactively then you must set threshold to a value other than 0. 
 
<source lang="python">
# in CASA
weighting = 'briggs'
robust=0.5
niter=1000
threshold = '0.0mJy'
</source>
 
For more information on the various options available in {{clean}}, refer to [https://science.nrao.edu/science/meetings/2016/15th-synthesis-imaging-workshop/documents/wilner_vla16.pdf David Wilner’s Imaging and Deconvolution presentation] from the 2016 Synthesis Imaging Workshop. Use this table to find specific slides for different parameters you will set below.
 
{| class="wikitable"
|+Imaging Parameters
|-
|Pixel and Image Size
|Slides 40-41
|-
|Weighting
|Slides 42-48, 60-61
|-
|Deconvolution Algorithms
|Slides 50-53, 62
|}
 
== Create an Averaged Continuum MS ==
<figure id="Calibrated_final_Field0_Spw0.png">
[[File:Calibrated_final_Field0_Spw0.png|thumb|<caption>spw 0</caption>]]
</figure>
<figure id="Calibrated_final_Field0_Spw3.png">
[[File:Calibrated_final_Field0_Spw3.png|thumb|<caption>Plots showing each spectral window for TW Hydra with channel vs amplitude. Spw 0 has a strong spectral line and spw 3 is a continuum only window.</caption>]]
</figure>
Create a separate, spectrally-averaged continuum measurement set in order to increase the efficiency of {{clean}}/{{tclean}}. The process below identifies line free channels and creates this measurement set.
The first step is to identify spectral lines in all spectral windows(spw) you will use to make the continuum image. Include all spectral windows with greater than 250 MHz bandwidth in order to maximize the continuum bandwidth. If you find spectral line emission you will need to flag these channels from the spw before imaging.
 
There are currently two methods to determine which channels have spectral line emission. The first is to simply use CASA to plot Channel vs Amp of each spw and note the channels with emission. You may wish to change the averaging and uvrange to identify extended emission:


<source lang="python">
<source lang="python">
Line 154: Line 48:
</source>
</source>


The second, and more accurate, method is to use {{clean}} to make a quick dirty image cube of channels with niter set to zero and mode=’channel’. Inspecting this channel cube for line emission gives a better defined channel range to flag. The command below gives the basic command to create dirty image cubes. This should be repeated for each spw and science field.
The second, and more accurate, method is to use {{tclean}} to make a quick dirty image cube of channels with niter set to zero and mode=’channel’. Inspecting this channel cube for line emission gives a better defined channel range to flag. The basic command to create dirty image cubes is given below. If you are going to use this method, you will need to set the [[Image_Continuum#Image_Parameters | imaging parameters]] before running the {{tclean}} command. This command should be repeated for each spw and science field.  


<source lang="python">
<source lang="python">
#In CASA  
#In CASA  


testimagename=’testImage’
testimagename=’testImage’
field=[‘0’] #list all target fields
field=['0'] #list all target fields
spw=[‘0,1,2,3’] #list all target spw’s
spw=['0','1','2','3'] #list all target spw’s


for i in field:
for i in field:
       for j in spw:   
       for j in spw:   
             clean(vis=finalvis,
             tclean(vis=finalvis,
               imagename=testimagename+’Field_’+str(i)+’_spw_’+str(j),  
               imagename=testimagename+'Field_'+str(i)+'_spw_'+str(j),  
               field=str(i),
               field=str(i),
                 spw=str(j),
                 spw=str(j),
          #     phasecenter=phasecenter, # uncomment if mosaic.    
                  # phasecenter=phasecenter, # uncomment if mosaic and set to appropriate field number
                 mode='channel',
                  # phasecenter='TRACKFIELD' # uncomment if imaging an ephemeris object, the phasecenter needs to be TRACKFIELD, not a field number as above.
                 outframe=outframe,  
                 specmode='cube',
                  veltype=veltype,
                  nchan=-1,
                 outframe='REST', # velocity reference frame. See science goals
                 niter=0,
                 niter=0,
                 interactive=True,
                 interactive=True,
Line 179: Line 75:
                 weighting=weighting,  
                 weighting=weighting,  
                 robust=robust,
                 robust=robust,
                 imagermode=imagermode)
                  pbcor=True,
                  restoringbeam='common',
                 gridder=gridder)
</source>
</source>


Once you have determined which spws have line emission and which ones you would like to use to form the continuum from your measurements, set the continuum spws to use:
[[File:Wt_vs_Freq_spw0123.png|thumb|Figure 3: The weight spectrum vs Frequency for the calibrated_final.ms for each science spectral window. Notice how the weights in each individual spectral window do not vary wildly and have no outliers but the overall weight measure is different for each spectral window due to the different observing frequency.]]


<source lang="python">
The first step to flagging the spectral line channels in your data is to use the {{flagmanager}} task to save the state of the data before any flagging is applied. You will need to revert back to the non spectral line flagged dataset when line imaging is done later on. In addition, if you accidentally flag any data you can easily correct this by restoring the before_cont_flags file using the {{flagmanager}}.
# in CASA
# Set spws to be used to form continuum
contspws = '0,1,2,3'
</source>
<figure id="Wt_vs_Freq_spw0123.png">
[[File:Wt_vs_Freq_spw0123.png|thumb|<caption>The weight spectrum vs Frequency for the calibrated_final.ms for each science spectral window. Notice how the weights in each individual spectral window do not vary wildly and have no outliers but the overall weight measure is different for each spectral window due to the different observing frequency.</caption>]]
</figure>
The first step to flagging the spectral line channels in your data is to use the {{flagmanager}} task to save the state of the data before any flagging is applied. You will need to revert back to the non spectral line flagged dataset when line imaging is done later on. In addition, if you accidentally flag any data you can easily correct this using the *.before_cont_flags file.


<source lang="python">
<source lang="python">
Line 200: Line 90:
</source>
</source>


Initialize the weights in the ms using [https://casa.nrao.edu/docs/TaskRef/initweights-task.html initweights].
Initialize the per-channel (or spectral) weights in the ms using [https://casa.nrao.edu/docs/TaskRef/initweights-task.html initweights]. This step ensures that when the flagged and unflagged channels are combined, the appropriate weighting is given to the final set of averaged channels. Figure 3 shows a representation of the weightspectrum vs. frequency plot you should see after initializing the spectral weights.


<source lang="python">
<source lang="python">
Line 213: Line 103:
flagchannels='2:1201~2199,3:1201~2199' # modify the channel range for your dataset
flagchannels='2:1201~2199,3:1201~2199' # modify the channel range for your dataset
</source>
</source>
<figure id="Calibrated_final_field0_spw0_LineChannelFlagged.png">
 
[[File:Calibrated_final_field0_spw0_LineChannelFlagged.png|thumb|<caption>Amp vs channel for spectral window 0 for TW Hydra with the spectral line flagged out. </caption>]]
[[File:Calibrated_final_field0_spw0_LineChannelFlagged.png|thumb|Figure 4: Amp vs channel for spectral window 0 for TW Hydra with the spectral line flagged out.]]
</figure>
 
Next, use the task {{flagdata}} to apply these flags. After this is done it is good to check that the flags were applied correctly by using plotms to inspect the flagged ms.
Next, use the task {{flagdata}} to apply these flags. After this is done, check that the flags were applied correctly by using plotms to inspect the flagged ms. Figure 4 shows an example of what you should expect to see.


<source lang="python">
<source lang="python">
Line 229: Line 119:
</source>
</source>


Before imaging the continuum there are several things that can be done to speed up cleaning of the final continuum image. One of these is to spectrally average several channels together within a single continuum window thus reducing the total number of channels while maintaining the same bandwidth.
Now you can spectrally average the channels together to reduce the size of the continuum ms. The number of channels that you can average together is limited by what is referred to as "bandwidth smearing". When creating an interferometer image, we assume that the emission is essentially monochromatic. If you average large numbers of channels together, this is no longer an appropriate assumption and results in radial smearing in the image that increases in magnitude from the delay tracking center. For a detailed discussion, consult [http://adsabs.harvard.edu/abs/1999ASPC..180..371B Bridle and Schwab, 1999, Synthesis Imaging in Radio Astronomy II, 180, 371]. For a short derivation of the relevant quantities, see  [https://safe.nrao.edu/wiki/pub/Main/RadioTutorial/BandwidthSmearing.pdf How to Calculate Bandwidth Smearing]. Conservative values for averaging channels in various ALMA bands are suggested below.  As a rough guide, the number of channels you can average together is:
* Bands 3, 4, 5, and 6: 125MHz/ (Channel Width (MHz))
* Bands 7, 8, 9 and 10: 250MHz/ (Channel Width (MHz))


Refer to [https://safe.nrao.edu/wiki/pub/Main/RadioTutorial/BandwidthSmearing.pdf How to Calculate Bandwidth Smearing] for the derivation of the information about bandwidth smearing. Conservative values for various ALMA bands are suggested below.
In general, you should make sure that the number of channels you are averaging together is an integer multiple of the original total number of channels. For example, if you have 128 channels and a channel width of 15.625 MHz in band 6, you can average together 8 channels at a time. The resulting ms will contain 16 final channels each with a channel width of 125MHz.


[[Image:Bandwidthsmearingtable.png|center|frame|1200px]] ''This table lists the maximum bandwidth allowed for a reduction in peak response to a point source over the field of view of 1% for a a square and Gaussian bandpass. This tables lists this for various observing frequencies and baselines for the two bandpass cases. For example, if your observation was at 385 GHz and your maximum baseline was 10,000 meters then for a Gaussian bandpass the maximum bandwidth that can be averaged together is 109.62 MHz bandwidth.''
If you want to be more careful, the following table will tell you the maximum bandwidth each averaged channel can be to avoid bandwidth smearing worse than about 1%. For example, at Band 7 (373 GHz) in a compact configuration (Bmax=500m) bandwidth smearing is relatively unimportant even for wide bandwidths (2.1 GHz), whereas for extended configurations (Bmax=10km) the maximum bandwidth at the same Band 7 should be of order 100 MHz or less.


125MHz/ChanWid(MHz) = number of channels to average for bands 3,4,5,6
[[Image:Bandwidthsmearingtable.png|center|frame|1200px]] ''This table lists the maximum bandwidth allowed for a reduction in peak response to a point source over the field of view of 1% for a a square and Gaussian bandpass for various observing frequencies and baselines for different two bandpass types. See [https://safe.nrao.edu/wiki/pub/Main/RadioTutorial/BandwidthSmearing.pdf How to Calculate Bandwidth Smearing] for more information.''
250MHz/ChanWid(MHz) = number of channels to average for band 7


For example, if you have 128 channels and a channel width of 15.625 MHz in band 6, the way to find the number of channels to average together is
Finally, the task {{split}} is used to average the channels together to produce the spectrally averaged continuum data set.
 
125 MHz / 15.625 MHz = 8 channels
It is always a good check to make sure the number of channels you are averaging together is an integer multiple of the total number of channels original. This will tell you how many channels will remain in the ms. Using the example above averaging every 8 channels of  128 channels leaves 16 final channels each with a channel width of 125MHz.
{{Split}} averages the number of channels you specify within the width command and will save a new ms file called calibrated_final_cont.ms.
<source lang="python">
<source lang="python">
# in CASA
# in CASA
Line 251: Line 136:
rmtables(contvis)
rmtables(contvis)
os.system('rm -rf ' + contvis + '.flagversions')
os.system('rm -rf ' + contvis + '.flagversions')
split2(vis=finalvis,
split(vis=finalvis,
spw=contspws,
    spw=contspws,    
outputvis=contvis,
    outputvis=contvis,
width=[8,8,8,8], # number of channels to average together. The final channel width should be less than 125MHz in Bands 3, 4, and 6 and 250MHz in Band 7.
    width=[256,8,8,8], # number of channels to average together. The final channel width should be less than 125MHz in Bands 3, 4, and 6  
datacolumn='data')
    # and 250MHz in Bands 7, 8, 9 and 10.
    datacolumn='data')
</source>
</source>


Now you should check the weights of the new continuum measurement set. The ratio of the weights value between Time Domain Mode (TDM) and Frequency Domain Mode (FDM) windows should be approximately equal to the ratio of the channel widths.
Now you should check the weights of the new continuum measurement set. The ratio of the weights value between Time Domain Mode (TDM) and Frequency Domain Mode (FDM) windows should be approximately equal to the ratio of the channel widths. For more information on the correlator modes TDM and FDM, see section 5.1 of the [https://almascience.nrao.edu/documents-and-tools/cycle5/alma-technical-handbook ALMA Technical Handbook]. In addition, any heavily flagged channels should have their weights scaled by the ratio of the unflagged bandwidth to the bandwidth per output channel. For more information about data weights, see the [https://casaguides.nrao.edu/index.php/DataWeightsAndCombination Data Weights and Combination] guide.


<source lang="python">
<source lang="python">
Line 266: Line 152:
</source>
</source>


Use {{flagmanager}} to restore the ms file to its original unflagged state.
Finally, we need to use  the {{flagmanager}} tasks to restore the ms file to its original unflagged state, so that later we can do continuum subtraction and line imaging.
<figure id="Amp_vs_uvdist.png">
[[File:Amp_vs_uvdist.png|thumb|Figure 5: Amplitude vs UVDistance plot of the continuum, colored by spw.]]
[[File:Amp_vs_uvdist.png|thumb|<caption>Amplitude vs UVDistance plot of the continuum, colored by spw.</caption>]]
 
</figure>
<source lang="python">
<source lang="python">
# in CASA
# in CASA
Line 277: Line 162:
</source>
</source>


It is a good practice to inspect the continuum after this in order to confirm it is alright for future cleaning.The uv-coverage should be consistent and you should not see large outliers.
It is a good practice to inspect the final continuum ms to make sure that it is correct. In general, the distribution of amplitude vs. uv distance should be smooth. Recall this plot will be a horizontal line for a point source, while the short uv-distances will have higher amplitudes for a more extended object.  


<source lang="python">
<source lang="python">
Line 284: Line 169:
</source>
</source>


== Imaging the Continuum ==
== Image Parameters ==
<figure id="Cont_before_clean.png">
 
[[File:Cont_before_clean.png|thumb|<caption>During interactive {{clean}}, the GUI will show an initial dirty image. From this GUI, create the {{clean}} mask.</caption>]]
Before imaging, you should set a few key parameters that you will use throughout the rest of the script.  
</figure>
 
<figure id="Cont_before_clean_mask.png">
Set the field id for the science target you are interested in imaging. You can use the listobs file generated during the imaging prep step to find this information. If you are imaging a mosaic then you will have to select all the fields. For example, field = ‘3~25’. You can also set the field variable to the name of the source, as long as it matches the name in the listobs file. Do not leave the field parameter blank. If you leave the field parameter blank, {{tclean}} will attempt to image all sources in the measurement set.
[[File:Cont_before_clean_mask.png|thumb|<caption>After a mask is created, the green arrow will be illuminated. Press this to begin the first 100 iterations. Once cleaning is complete, press the red "X" to finish.</caption>]]
 
</figure>
<source lang="python">
<figure id="Final_Cont_residual.png">
# in CASA
[[File:Final_Cont_residual.png|thumb|<caption>The final residual image.</caption>]]
# update for your ms
</figure>
field='0'
Now that you have set all of the imaging parameters you will need in {{clean}} you can proceed to imaging the continuum. The [https://casaguides.nrao.edu/index.php/First_Look_at_Imaging First Look at Imaging CASAGuide] gives an introduction to cleaning and imaging.  
</source>
 
Uncomment the gridder that is relevant to your dataset. Set the phase center by field id or coordinates if you are imaging a mosaic. Check the spatial setup in the weblog (for pipeline calibrations) or qa2 report (for manual calibrations) to find the phase center. You should choose the central field for the phase center in order to get the best results.  
 
If you are unsure which field to use for the phase center after looking at the weblog then you may use the following Analysis Utilities command:
 
<source lang="python">
au.pickCellSize('calibrated_final.ms',imsize=True).  
</source>
 
This will return a four element array with that contains the calculated cell size, the X axis number of pixels, the Y axis number of pixels, and the field number that is most centered in the mosaic. You may use this as the phase center field id in your script. If you haven't installed Analysis Utilities, see [https://casaguides.nrao.edu/index.php?title=Analysis_Utilities Obtaining Analysis Utilities] for instructions.
 
Another method of finding the central field number uses the Analysis Utilities [https://casaguides.nrao.edu/index.php/Plotmosaic plotmosaic] au.plotmosaic(‘calibrated_final.ms’). This method will produce a plot of all fields with their corresponding field numbers plotted on the sky. You can also set the phase center with the coordinates at the center of this plot.
 
For ephemeris objects such as planets, the outframe should be set to phasecenter = 'TRACKFIELD', not a field number as above.


<source lang="python">
<source lang="python">
# in CASA
# in CASA
contvis = 'calibrated_final_cont.ms'        
# gridder='standard' # uncomment if single field
contimagename = 'calibrated_final_cont'
# gridder='mosaic' # uncomment if mosaic or if combining one 7m and one 12m pointing.
# phasecenter=3 # uncomment and set to field number for phase
                # center. Note lack of ''.  Use the weblog to
                # determine which pointing to use. Remember that the
                # field ids for each pointing will be re-numbered
                # after your initial split. You can also specify the
                # phase center using coordinates, e.g.,
                # phasecenter='J2000 19h30m00 -40d00m00'.
# phasecenter = 'TRACKFIELD' # If imaging an ephemeris object (planet, etc), the phasecenter needs to be TRACKFIELD, not a field number as above.
</source>
</source>


If you have already run {{clean}} on the ms and would like to start over, be sure to use the following commands before cleaning the continuum.
[[File:Calibrated_final_AmpVsUVWave.png|thumb|Figure 6: Amplitude versus UV wave for the calibrated_final.ms showing the maximum uv wave point for determining cell size.]]


Next, determine the cell (or pixel) size. To do this, you need to determine the approximate resolution of your observations. Then you divide the resolution in arcsec by 5 to 8 to adequately sample the PSF. The resolution of a particular interferometer observations can be estimated from the length of the longest baseline:
<pre style="background-color: #E0FFFF;">
resolution (radian) ~ (observed wavelength) / (length of longest baseline)
</pre>
If the baseline is measured in wavelengths, this becomes
<pre style="background-color: #E0FFFF;">
resolution (radian) ~ 1.0 / (length of longest baseline in wavelengths)
</pre>
To convert from radians to arcsec, we multiple by 206265.0 to obtain:
<pre style="background-color: #E0FFFF;">
resolution(arcsec) ~ 206265.0/(longest baseline in wavelengths)
</pre>
To determine the longest baseline in wavelengths use plotms with xaxis=’uvwave’ and yaxis=’amp’ on your ms file. Figure 6 shows an example of this plot. It is generally better to oversample your beam than to undersample, particularly for observations with poor uv-coverage.
<pre style="background-color: #E0FFFF;">
cellsize(arc seconds) = resolution(arcsec)/7
</pre>
The next step is to determine the image size in pixels. There are two methods of doing this depending on if you are imaging one field or a mosaic.
If this is a single field, the image size can usually be approximated to be the same size as the primary beam of the telescope. The ALMA 12m primary beam in arcsec scales as 6300 / nu[GHz] and the ALMA 7m primary beam in arcsec scales as 10608 / nu[GHz], where nu[GHz] is the sky frequency. However, if there is significant point source and/or extended emission beyond the edges of your initial images, you should increase the imsize to incorporate more emission.
For mosaics, make the image substantially larger than the mosaic footprint. Use au.plotmosaic(finalvis) to find the mosaic footprint in arcseconds. Padding the imsize substantially avoids artifacts in the image. You should be able to see the edges of the outside fields being cut off in an appropriately padded image. In Figure 7 you will see a mosaic field under padded with the edges not visible. Figure 8 shows an image made with a larger imsize of the same mosaic with the edges clearly visible.
[[File:Antennae_Antennae_North.Cont.Dirty.image.png|thumb|Figure 7]]
[[File:Antennae_North.Cont.Dirty.smallIMSize.image.png|thumb|Figure 8: A mosaic of Antennae showing under padding and correctly padded images. For the correctly padded image you can see the edges of the primary beam field whereas the under padded does not cut off.]]
Note that the imsize parameter is in PIXELS, not arcsec, so you will need to divide the image size in arcsec by the pixel size to determine a value for imsize.
If you would like to check any of these calculations you may use the following command, [https://safe.nrao.edu/wiki/bin/view/ALMA/PickCellSize au.pickCellSize]('calibrated_final.ms', imsize=True), in CASA. If you haven't installed Analysis Utilities, see [https://casaguides.nrao.edu/index.php?title=Analysis_Utilities Obtaining Analysis Utilities] for instructions. This will return a four element array of the calculated cell size, the x axis imsize, the y axis imsize, and the central field id number.
<source lang="python">
<source lang="python">
# in CASA
# in CASA
# Clearcal clears the calibrated column of the ms.
cell='1arcsec' # cell size for imaging.
# clearcal(contvis)
imsize = [128,128] # size of image in pixels.
# Delmod removes any model column put in by clean.
# delmod(contvis)
</source>
</source>


{{Clean}} creates a variety of files after it completes. If these files exist in the directory, {{clean}} will begin working on the files that already exist. The following command will delete all of these files. You may also change the cont_image_name parameter if you would like to keep the files you created previously.
When imaging lines, you will need to set two specific velocity parameters called outframe and veltype. Outframe is the coordinate system used for the observation. If you have access to the original proposal, this can be found in the Observing Tool (OT) under field setup. A list of acceptable outframes that can be used in CASA can be found at https://help.almascience.org/kb/articles/what-are-the-frequency-reference-frames-in-casa. Note: heliocentric(hel) is deprecated in CASA. Use barycentric(bary) in this case. The most common choices are 'bary' and 'lsrk'. Usually 'bary' is used for sources where z>0.2 ('extragalactic") and 'lsrk is used for 'galactic' sources. For ephemeris objects, the outframe should be set to a blank string, for example outframe =  <nowiki>''</nowiki>, as you have likely already regridded to the source velocity in cvel() or can allow tclean to do it on the fly.
 
You will also have to set the veltype for the {{tclean}} command. This variable has only two options available, radio and optical. Due to an interaction between the ALMA Observing Tool and CASA, set the veltype to radio. Even if the object has an optically defined velocity, the sensitivity calculation uses the radio definition. This will avoid confusion in comparing the achieved sensitivity to the expected sensitivity.  


<source lang="python">
<source lang="python">
# in CASA
# in CASA
for ext in ['.flux','.image','.mask','.model','.pbcor','.psf','.residual','.flux.pbcoverage','.pb','.wtsum']:
outframe='lsrk' # velocity reference frame. See science goals.
rmtables(contimagename+ext)
veltype='radio' # velocity type.
</source>
</source>


If you are imaging a mosaic, the phasecenter parameter should be setRefer to the imaging parameters section of this guide to see how to find this for your project.
The last four parameters that must be set are associated with how {{tclean}} will weight and clean the data.  During the imaging process, the individual visibilities are placed on a uv grid and then combined. Weighting determines how {{tclean}} will combine the uv gridded to produce an image. There are several weighting schemes that can be used:
 
* Natural: Each cell in the uv plane is weighted by the number of points in the cell. This weighting scheme is the default in {{tclean}}. It results in a lower noise image at the expense of  worse angular resolution.
 
* Uniform: Each cell in the uv plane has the same weight.  In this case, the sidelobes will be reduced because the imaging plane is filled in more uniformly. This weighting scheme also gives more weight to longer baselines resulting in higher resolution at the expense of higher noise. It can emphasize visibilities with calibration errors.


Type “help clean()” in CASA if you would like to explore the possible parameters of {{clean}}. Mode=’mfs’ sets the spectral gridding type to multi-frequency synthesis and creates a continuum image. Leave the psfmode to use during minor cycles at the default ‘clark’ .
* Briggs: This weighting scheme is a combination of natural and uniform weighting. The weighting is controlled by the robust parameter. A robust parameter of 2 gives natural weighting, -2 uniform weighting, and a number in between a combination of natural and uniform. Refer to [https://casadocs.readthedocs.io/en/stable/notebooks/memo-series.html?highlight=briggs#Dan-Briggs'-Dissertation---Robust-Weighting Brigg's Thesis] for more information. Currently, robust is set to 0.5, which gives a good compromise between natural and uniform weighting. You may find, after imaging, that you have to decrease the noise or angular resolution based on the science goals. Playing with the robust parameter can affect your final noise in the image and also the angular resolution. If you are making a mosaic image do not use a robust value smaller than 0 as this may introduce major artifacts in the images including uneven noise across the image. If you choose to do any form of uvtapering to the data in tclean(), set robust to 2 (Natural weighting) to avoid upweighting points that are going to be downweighted by uv-taper.


{{Clean}} interactively as the threshold is set at 0 mJy. The mask parameter may also be added if you have an existing file.
The parameters niter and threshold provide two ways to stop the {{tclean}} process.  The niter parameter is the maximum number of iterations allowed. After this limit has been reached, {{tclean}} will terminate. The threshold parameter sets a flux density threshold for the {{tclean}}. When the peak residual is below this value, {{tclean}} terminates. When cleaning interactively, we recommend setting the niter parameter to a large(say 1000), but not too large value (say 10000 or 100000) so that {{tclean}} terminates eventually in the case of human error. The threshold can be left at the default of 0.0mJy for interactive tclean. For non-interactive tclean, the recommendation is to set the threshold to several times the noise in the final image.  To determine the threshold for cube images, run tclean with niter set to zero and inspect the resulting image in the {{viewer}}. In a line-free channel, select a region and look at the statistics panel to determine the noise level. For more detailed instructions, see the “Image the Spectral Line Data” section of [https://casaguides.nrao.edu/index.php?title=EVLA_Spectral_Line_Imaging_Analysis_IRC%2B10216 EVLA Spectral Line Imaging Analysis IRC+10216].


<source lang="python">
<source lang="python">
# in CASA
# in CASA
clean(vis=contvis,
weighting = 'briggs'
      imagename=contimagename,
robust=0.5
      field=field,
niter=1000
#      phasecenter=phasecenter, # uncomment if mosaic.     
threshold = '0.0mJy'
      mode='mfs',
      psfmode='clark',
      imsize = imsize,
      cell= cell,
      weighting = weighting,
      robust = robust,
      niter = niter,
      threshold = threshold,
      interactive = True,
      imagermode = imagermode)
</source>
</source>


Figure 11 shows the {{clean}} GUI that will appear. If no source is apparent, no cleaning should be done. Press the red “X” to complete the task. If a source is apparent, create a mask around it. Once a mask is created, the green arrow will be illuminated and you can begin the first round of cleaning.  
For more information on the various options available in {{tclean}}, refer to [https://science.nrao.edu/science/meetings/2016/15th-synthesis-imaging-workshop/documents/wilner_vla16.pdf David Wilner’s Imaging and Deconvolution presentation] from the 2016 Synthesis Imaging Workshop. The table below provides helpful pointers to relevant slides.


The logger window gives you vital information on the progression of {{clean}}. Once the cycle is complete, the residuals will appear in the GUI. You should continue to iterate until the region inside the mask matches the noise outside the mask. You may need multiple cycles depending on the complexity of the source.
{| class="wikitable"
|+Imaging Parameters
|-
|Pixel and Image Size
|Slides 40-41
|-
|Weighting
|Slides 42-48, 60-61
|-
|Deconvolution Algorithms
|Slides 50-53, 62
|}


The red "X" will stop {{clean}} where you are, the blue arrow will stop the interactive part of {{clean}}, but continue to clean non-interactively until reaching the number of iterations requested (niter) or the flux density threshold (whichever comes first), and the green circle arrow will clean until it reaches the "iterations" parameter on the left side of the green area. These are the only safe exit buttons to use during {{clean}}. Otherwise  your data may be corrupted.
== Imaging the Continuum ==
[[Image:Final_Continuum_Image.png|center|frame|800px]] ''The final continuum image.''
[[File:Cont_before_clean.png|thumb|Figure 9: During interactive {{tclean}}, the GUI will show an initial dirty image. From this GUI, create the {{tclean}} mask.]]
After creating the continuum image, check the RMS and beam size to make sure the results match the expected values.
[[File:Cont_before_clean_mask.png|thumb|Figure 10: After a mask is created, the green arrow will be illuminated. Press this to begin the first 100 iterations. Once cleaning is complete, press the red "X" to finish.]]
Once you are happy with your continuum image(s), you can continue to '''[[Self_Calibration_Template | Self-Calibration Template]]''' or '''[[Image_Line | Spectral Line Imaging Template]]'''. If you do not wish to self-calibrate or create line cubes, continue with this guide to create primary beam corrected images and fits files.
[[File:Final_Cont_residual.png|thumb|Figure 11: The final residual image.]]
Now that you have set all of the imaging parameters you will need in {{tclean}}, you can proceed to imaging the continuum. The [https://casaguides.nrao.edu/index.php/First_Look_at_Imaging First Look at Imaging CASAGuide] gives an introduction to cleaning and imaging. You may also find the [https://casaguides.nrao.edu/index.php/Automasking_Guide Automasking Guide] useful in allowing {{tclean}} to generate the mask used for cleaning automatically.
 
We provide an abbreviated set of commands here.  
If you are imaging a mosaic, the phasecenter parameter should be set.  Refer to the [[Image_Continuum#Image Parameters | Image Parameters]] section of this guide for instructions on how to determine this for your project. Type “help tclean()” in CASA if you would like to explore the possible parameters of {{tclean}}. Specode=’mfs’ sets the spectral gridding type to multi-frequency synthesis and creates a continuum image. If you are imaging the aggregate continuum in Band 3 or 4 and have a fractional bandwidth larger than 10%, you should consider using multi-term multi-frequency synthesis (deconvolver='mtmfs' and nterms=2). This tclean mode accounts for spatial spectral index variations and especially important to include if you have a spatially resolved, high S/N source. For more information on multi-term multi-frequency synthesis, see [https://www.aanda.org/articles/aa/pdf/2011/08/aa17104-11.pdf Rau, U., & Cornwell, T.J. 2011, A&A, 532, AA71].
Clean interactively as the threshold is set at 0 mJy. The mask parameter may also be added if you have an existing file. You can create a mask from the dirty image using the instructions at [[Create_a_Clean_Mask_from_Continuum_Image_or_Moment_Cube]].


== Apply a primary beam correction ==
In CASA 5.4 and later, {{tclean}} calls with gridder = 'mosaic' have an additional parameter mosweight with a default of True. When mosweight = True, the gridder weights each field in the mosaic independently. The mosweight parameter is particularly important for mosaics with non-uniform sensitivity, with rectangular shapes, or when using more uniform values of robust Briggs weighting. For more information on mosweight, please see the {{tclean}} documentation.
<figure id="TW_Hya_Calibrated_final.pbcor.png">
[[File:TW_Hya_Calibrated_final.pbcor.png|thumb|<caption>TW Hydra image after a primary beam correction is applied to correct the lower rms found at the edges of the images from the primary beam.</caption>]]
</figure>
Once all imaging is finished, diagnostic images will be made. The first of these is a primary beam correction image of the data. Each telescope's primary beam is, for the most part, approximately a Gaussian with small side lobes that can be approximated to zero. Because of this, the center of the beam has much more sensitivity than the edges. To correct for this, flux is added to the edges of the image in order for all pixels across the beam to have the same relative brightness based on the beam pattern.  


{{Impbcor}} is used to produce the primary beam corrected images . You will need the *.flux and *.pbcor files.  
<source lang="python">
# in CASA
contvis = 'calibrated_final_cont.ms'       
contimagename = 'calibrated_final_cont'
</source>


<source lang="python">
<source lang="python">
# in CASA
# in CASA
import glob
tclean(vis=contvis,
      imagename=contimagename,
      field=field,
      #  phasecenter=phasecenter, # uncomment if mosaic or imaging an ephemeris object
      #  mosweight=True, # uncomment if mosaic   
      specmode='mfs',
      deconvolver='hogbom',
      # Uncomment the below to image with nterms>1. Use if fractional bandwidth is >10%.
      #deconvolver='mtmfs',
      #nterms=2,
      imsize = imsize,
      cell= cell,
      weighting = weighting,
      robust = robust,
      niter = niter,
      threshold = threshold,
      interactive = True,
      gridder = gridder,
      pbcor = True,
      usepointing=False)
</source>
 
Figure 9 shows the {{tclean}} GUI that will appear. If no source is apparent, no cleaning should be done. Press the red “X” to complete the task. If a source is apparent, create a mask around it using the mouse. Once a mask is created, the green arrow will be illuminated and you can begin the first round of cleaning.  Figure 10 shows what a mask would look like for our example source. The logger window gives you vital information on the progression of {{tclean}}. Once the cycle is complete, the residuals will appear in the GUI. You should continue to iterate until the region inside the mask matches the noise outside the mask. You may need multiple cycles depending on the complexity of the source. Figure 11 shows an example of when we chose to stop cleaning.
 
The red "X" will stop {{tclean}} where you are, the blue arrow will stop the interactive part of {{tclean}}, but continue to clean non-interactively until reaching the number of iterations requested (niter) or the flux density threshold (whichever comes first), and the green circle arrow will clean until it reaches the "iterations" parameter on the left side of the green area. These are the only safe exit buttons to use during {{tclean}}. DO NOT CTRL-C OR KILL TCLEAN WHILE IT IS RUNNING. If you do this, it is very likely that your ms will be corrupted.
 
[[Image:Final_Continuum_Image.png|center|frame|800px]] ''The final continuum image.''
 
After creating the continuum image, check the noise and resolution to make sure the results match the expected values. Use the [https://almascience.nrao.edu/proposing/sensitivity-calculator ALMA Sensitivity Calculator] to estimate the expected sensitivity.


myimages = glob.glob("*.image")
For each image it creates, {{tclean}} generates several images with the name imagename+extension. If you re-run tclean with the same imagename, {{tclean}} will use the existing files as a starting point, continuing the tclean where you left off. To start completely from scratch, either change the imagename or delete all the files from the previous {{tclean}} run. Note that CASA retains some image information in memory, so to truly delete the images, you need to run the {{rmtables}} command. You will also want to remove datacolumns that were added by tclean with {{clearcal}} and {{delmod}}. See below for an example.


rmtables('*.pbcor')
<source lang="python">
for image in myimages:
# in CASA
pbimage = image.rsplit('.',1)[0]+'.flux'
clearcal(contvis)
outfile = image.rsplit('.',1)[0]+'.pbcor'
delmod(contvis)
impbcor(imagename=image, pbimage=pbimage, outfile = outfile)
for ext in ['.image','.mask','.model','.image.pbcor','.psf','.residual','.pb','.sumwt']:
    rmtables(contimagename+ext)
</source>
</source>
Once you are happy with your continuum image(s), you can continue to '''[[Self_Calibration_Template | Self-Calibration Template]]''' or '''[[Image_Line | Spectral Line Imaging Template]]'''. If you do not wish to self-calibrate or create line cubes, continue with this guide to create primary beam corrected images and fits files.


== Export the images ==
== Export the images ==
Line 386: Line 368:
     exportfits(imagename=image, fitsimage=image+'.fits',overwrite=True)
     exportfits(imagename=image, fitsimage=image+'.fits',overwrite=True)


myimages = glob.glob("*.flux")
myimages = glob.glob("*.pb")
for image in myimages:
for image in myimages:
     exportfits(imagename=image, fitsimage=image+'.fits',overwrite=True)
     exportfits(imagename=image, fitsimage=image+'.fits',overwrite=True)  
 
</source>
</source>


Line 394: Line 377:


[https://casaguides.nrao.edu/index.php/First_Look_at_Image_Analysis The First Look at Image Analysis] guide gives an introduction to a variety of options to begin image analysis, including using {{immoments}} to create moment maps.
[https://casaguides.nrao.edu/index.php/First_Look_at_Image_Analysis The First Look at Image Analysis] guide gives an introduction to a variety of options to begin image analysis, including using {{immoments}} to create moment maps.
The commands create png files of the continuum image and moment 8 maps.  
The following commands create png files of the continuum image.


<source lang="python">
<source lang="python">
# in CASA
# in CASA
os.system("rm -rf *.png")
os.system("rm -rf *.png")
mycontimages = glob.glob("calibrated*.image")
mycontimages = glob.glob("*mfs*manual.image")
for cimage in mycontimages:
for cimage in mycontimages:
     max=imstat(cimage)['max'][0]
     mymax=imstat(cimage)['max'][0]
     min=-0.1*max
     mymin=-0.1*mymax
     outimage = cimage+'.png'
     outimage = cimage+'.png'
     os.system('rm -rf '+outimage)
     os.system('rm -rf '+outimage)
     imview(raster={'file':cimage,'range':[min,max]},out=outimage)
     imview(raster={'file':cimage,'range':[mymin,mymax]},out=outimage)
</source>
 
'''[[Guide_NA_ImagingTemplate | Return to the Main Page]]'''

Latest revision as of 20:33, 28 February 2024

This guide should be used after completing Prepare the data for Imaging. You should have created calibrated_final.ms prior to proceeding. Commands for this guide can be found in scriptForImaging_template.py available on github.

Check CASA version

This template is for use in CASA versions 6.1.1.15 and greater. The following code checks the version of CASA and exits if it is less than 6.1.1.15. You can download the appropriate version of CASA from Obtaining CASA . See Prepare for Imaging section on the main page of this guide for more information.

# in CASA
import re
try:
    import casalith
except:
    print("Script requires CASA 6.0 or greater")

if casalith.compare_version("<",[6,1,1,15]):
    print("Please use CASA version greater than or equal to 6.1.1-15 with this script")

Create an Averaged Continuum MS

Figure 1: spw 0
Figure 2: Plots showing each spectral window for TW Hydra with channel vs amplitude. Spw 0 has a strong spectral line and spw 3 is a continuum only window.

Appropriate averaging of a measurement set can reduce overall data volume, making imaging faster with tclean. Since the continuum image is formed by essentially summing the entire bandwidth, we can spectrally average the input measurement set prior to imaging without significantly affecting the final imaging results. Below, we outline a procedure to create a spectrally averaged measurement set for continuum imaging.

The first step is to identify which spectral windows (spws) you would like to include in the continuum. In general, you should include all spws with bandwidths greater than 250MHz to maximize the available continuum bandwidth. Once you have determined which spws you would like to use to form the continuum ms, set the contspw variable:

# in CASA
finalvis='calibrated_final.ms' # This is your output ms from the data
                               # preparation script.
# Set spws to be used to form continuum
contspws = '0,1,2,3'

The next step is to identify and flag the spectral lines in all spectral windows that you will use to make the continuum image. You will split and average the data with the spectral lines flagged so that your final spectrally averaged continuum ms only contains continuum emission. Two methods commonly used to identical spectral line emission are: 1) a channel vs. amplitude plot of the visibilities and 2) a dirty image of the cube.

To use the first method, create a channel vs. amplitude plot using plotms. An example command is given below. You may wish to change the averaging and the uvrange to identify extended emission.

Figures 1 and 2 show example plots of a spw with and without lines to flag. Figure 1 shows a clear line at channel 1700 whereas Figure 2 shows no line emission and just continuum.

Warning: If you apply channel averaging greater than 1, the numbers displayed on the channel axis will represent the channel bin number, rather than the averaged channel.

# in CASA
plotms(vis=finalvis, xaxis='channel', yaxis='amplitude',
   	ydatacolumn='data',
   	avgtime='1e8', avgscan=True, avgchannel='1',
   	iteraxis='spw' )

The second, and more accurate, method is to use tclean to make a quick dirty image cube of channels with niter set to zero and mode=’channel’. Inspecting this channel cube for line emission gives a better defined channel range to flag. The basic command to create dirty image cubes is given below. If you are going to use this method, you will need to set the imaging parameters before running the tclean command. This command should be repeated for each spw and science field.

#In CASA 

testimagename=testImage
field=['0'] #list all target fields
spw=['0','1','2','3'] #list all target spw’s

for i in field:
      for j in spw:  
            tclean(vis=finalvis,
            	  imagename=testimagename+'Field_'+str(i)+'_spw_'+str(j), 
            	  field=str(i),
      	          spw=str(j),
                  # phasecenter=phasecenter, # uncomment if mosaic and set to appropriate field number
                  # phasecenter='TRACKFIELD' # uncomment if imaging an ephemeris object, the phasecenter needs to be TRACKFIELD, not a field number as above.
      	          specmode='cube',
                  veltype=veltype,
                  nchan=-1,
      	          outframe='REST', # velocity reference frame. See science goals
      	          niter=0,
      	          interactive=True,
      	          cell=cell,
      	          imsize=imsize, 
      	          weighting=weighting, 
      	          robust=robust,
                  pbcor=True,
                  restoringbeam='common',
      	          gridder=gridder)
Figure 3: The weight spectrum vs Frequency for the calibrated_final.ms for each science spectral window. Notice how the weights in each individual spectral window do not vary wildly and have no outliers but the overall weight measure is different for each spectral window due to the different observing frequency.

The first step to flagging the spectral line channels in your data is to use the flagmanager task to save the state of the data before any flagging is applied. You will need to revert back to the non spectral line flagged dataset when line imaging is done later on. In addition, if you accidentally flag any data you can easily correct this by restoring the before_cont_flags file using the flagmanager.

# in CASA
flagmanager(vis=finalvis,mode='save',
versionname='before_cont_flags')

Initialize the per-channel (or spectral) weights in the ms using initweights. This step ensures that when the flagged and unflagged channels are combined, the appropriate weighting is given to the final set of averaged channels. Figure 3 shows a representation of the weightspectrum vs. frequency plot you should see after initializing the spectral weights.

# in CASA
initweights(vis=finalvis,wtmode='weight',dowtsp=True)

The exact spectral window and channel ranges to flag in the flagchannels variable needs to be specified. For example, if spws 2&3 have a line between channels 1201 and 2199 and spectral windows 0 and 1 are line-free the command would be:

# in CASA
flagchannels='2:1201~2199,3:1201~2199' # modify the channel range for your dataset
Figure 4: Amp vs channel for spectral window 0 for TW Hydra with the spectral line flagged out.

Next, use the task flagdata to apply these flags. After this is done, check that the flags were applied correctly by using plotms to inspect the flagged ms. Figure 4 shows an example of what you should expect to see.

# in CASA
flagdata(vis=finalvis,mode='manual',
      	spw=flagchannels,flagbackup=False)

# check that flags are as expected, NOTE must check reload on plotms
# gui if its still open.
plotms(vis=finalvis,yaxis='amp',xaxis='channel',
   	avgchannel='1',avgtime='1e8',avgscan=True,iteraxis='spw')

Now you can spectrally average the channels together to reduce the size of the continuum ms. The number of channels that you can average together is limited by what is referred to as "bandwidth smearing". When creating an interferometer image, we assume that the emission is essentially monochromatic. If you average large numbers of channels together, this is no longer an appropriate assumption and results in radial smearing in the image that increases in magnitude from the delay tracking center. For a detailed discussion, consult Bridle and Schwab, 1999, Synthesis Imaging in Radio Astronomy II, 180, 371. For a short derivation of the relevant quantities, see How to Calculate Bandwidth Smearing. Conservative values for averaging channels in various ALMA bands are suggested below. As a rough guide, the number of channels you can average together is:

  • Bands 3, 4, 5, and 6: 125MHz/ (Channel Width (MHz))
  • Bands 7, 8, 9 and 10: 250MHz/ (Channel Width (MHz))

In general, you should make sure that the number of channels you are averaging together is an integer multiple of the original total number of channels. For example, if you have 128 channels and a channel width of 15.625 MHz in band 6, you can average together 8 channels at a time. The resulting ms will contain 16 final channels each with a channel width of 125MHz.

If you want to be more careful, the following table will tell you the maximum bandwidth each averaged channel can be to avoid bandwidth smearing worse than about 1%. For example, at Band 7 (373 GHz) in a compact configuration (Bmax=500m) bandwidth smearing is relatively unimportant even for wide bandwidths (2.1 GHz), whereas for extended configurations (Bmax=10km) the maximum bandwidth at the same Band 7 should be of order 100 MHz or less.

This table lists the maximum bandwidth allowed for a reduction in peak response to a point source over the field of view of 1% for a a square and Gaussian bandpass for various observing frequencies and baselines for different two bandpass types. See How to Calculate Bandwidth Smearing for more information.

Finally, the task split is used to average the channels together to produce the spectrally averaged continuum data set.

# in CASA
contvis='calibrated_final_cont.ms'
rmtables(contvis)
os.system('rm -rf ' + contvis + '.flagversions')
split(vis=finalvis,
     spw=contspws,      
     outputvis=contvis,
     width=[256,8,8,8], # number of channels to average together. The final channel width should be less than 125MHz in Bands 3, 4, and 6 
     # and 250MHz in Bands 7, 8, 9 and 10.
     datacolumn='data')

Now you should check the weights of the new continuum measurement set. The ratio of the weights value between Time Domain Mode (TDM) and Frequency Domain Mode (FDM) windows should be approximately equal to the ratio of the channel widths. For more information on the correlator modes TDM and FDM, see section 5.1 of the ALMA Technical Handbook. In addition, any heavily flagged channels should have their weights scaled by the ratio of the unflagged bandwidth to the bandwidth per output channel. For more information about data weights, see the Data Weights and Combination guide.

# in CASA
# update the antenna and field parameters for your dataset
plotms(vis=contvis, yaxis='wtsp',xaxis='freq',spw='',antenna='DA42',field='0')

Finally, we need to use the flagmanager tasks to restore the ms file to its original unflagged state, so that later we can do continuum subtraction and line imaging.

Figure 5: Amplitude vs UVDistance plot of the continuum, colored by spw.
# in CASA
# If you flagged any line channels, restore the previous flags
flagmanager(vis=finalvis,mode='restore',
        	versionname='before_cont_flags')

It is a good practice to inspect the final continuum ms to make sure that it is correct. In general, the distribution of amplitude vs. uv distance should be smooth. Recall this plot will be a horizontal line for a point source, while the short uv-distances will have higher amplitudes for a more extended object.

# in CASA
plotms(vis=contvis,xaxis='uvdist',yaxis='amp',coloraxis='spw')

Image Parameters

Before imaging, you should set a few key parameters that you will use throughout the rest of the script.

Set the field id for the science target you are interested in imaging. You can use the listobs file generated during the imaging prep step to find this information. If you are imaging a mosaic then you will have to select all the fields. For example, field = ‘3~25’. You can also set the field variable to the name of the source, as long as it matches the name in the listobs file. Do not leave the field parameter blank. If you leave the field parameter blank, tclean will attempt to image all sources in the measurement set.

# in CASA
# update for your ms
field='0'

Uncomment the gridder that is relevant to your dataset. Set the phase center by field id or coordinates if you are imaging a mosaic. Check the spatial setup in the weblog (for pipeline calibrations) or qa2 report (for manual calibrations) to find the phase center. You should choose the central field for the phase center in order to get the best results.

If you are unsure which field to use for the phase center after looking at the weblog then you may use the following Analysis Utilities command:

au.pickCellSize('calibrated_final.ms',imsize=True).

This will return a four element array with that contains the calculated cell size, the X axis number of pixels, the Y axis number of pixels, and the field number that is most centered in the mosaic. You may use this as the phase center field id in your script. If you haven't installed Analysis Utilities, see Obtaining Analysis Utilities for instructions.

Another method of finding the central field number uses the Analysis Utilities plotmosaic au.plotmosaic(‘calibrated_final.ms’). This method will produce a plot of all fields with their corresponding field numbers plotted on the sky. You can also set the phase center with the coordinates at the center of this plot.

For ephemeris objects such as planets, the outframe should be set to phasecenter = 'TRACKFIELD', not a field number as above.

# in CASA
# gridder='standard' # uncomment if single field 
# gridder='mosaic' # uncomment if mosaic or if combining one 7m and one 12m pointing.
# phasecenter=3 # uncomment and set to field number for phase
                # center. Note lack of ''.  Use the weblog to
                # determine which pointing to use. Remember that the
                # field ids for each pointing will be re-numbered
                # after your initial split. You can also specify the
                # phase center using coordinates, e.g.,
                # phasecenter='J2000 19h30m00 -40d00m00'.
# phasecenter = 'TRACKFIELD' # If imaging an ephemeris object (planet, etc), the phasecenter needs to be TRACKFIELD, not a field number as above.
Figure 6: Amplitude versus UV wave for the calibrated_final.ms showing the maximum uv wave point for determining cell size.

Next, determine the cell (or pixel) size. To do this, you need to determine the approximate resolution of your observations. Then you divide the resolution in arcsec by 5 to 8 to adequately sample the PSF. The resolution of a particular interferometer observations can be estimated from the length of the longest baseline:

resolution (radian) ~ (observed wavelength) / (length of longest baseline)

If the baseline is measured in wavelengths, this becomes

resolution (radian) ~ 1.0 / (length of longest baseline in wavelengths)

To convert from radians to arcsec, we multiple by 206265.0 to obtain:

resolution(arcsec) ~ 206265.0/(longest baseline in wavelengths) 

To determine the longest baseline in wavelengths use plotms with xaxis=’uvwave’ and yaxis=’amp’ on your ms file. Figure 6 shows an example of this plot. It is generally better to oversample your beam than to undersample, particularly for observations with poor uv-coverage.

cellsize(arc seconds) = resolution(arcsec)/7 

The next step is to determine the image size in pixels. There are two methods of doing this depending on if you are imaging one field or a mosaic.

If this is a single field, the image size can usually be approximated to be the same size as the primary beam of the telescope. The ALMA 12m primary beam in arcsec scales as 6300 / nu[GHz] and the ALMA 7m primary beam in arcsec scales as 10608 / nu[GHz], where nu[GHz] is the sky frequency. However, if there is significant point source and/or extended emission beyond the edges of your initial images, you should increase the imsize to incorporate more emission.

For mosaics, make the image substantially larger than the mosaic footprint. Use au.plotmosaic(finalvis) to find the mosaic footprint in arcseconds. Padding the imsize substantially avoids artifacts in the image. You should be able to see the edges of the outside fields being cut off in an appropriately padded image. In Figure 7 you will see a mosaic field under padded with the edges not visible. Figure 8 shows an image made with a larger imsize of the same mosaic with the edges clearly visible.

Figure 7
Figure 8: A mosaic of Antennae showing under padding and correctly padded images. For the correctly padded image you can see the edges of the primary beam field whereas the under padded does not cut off.

Note that the imsize parameter is in PIXELS, not arcsec, so you will need to divide the image size in arcsec by the pixel size to determine a value for imsize.

If you would like to check any of these calculations you may use the following command, au.pickCellSize('calibrated_final.ms', imsize=True), in CASA. If you haven't installed Analysis Utilities, see Obtaining Analysis Utilities for instructions. This will return a four element array of the calculated cell size, the x axis imsize, the y axis imsize, and the central field id number.

# in CASA
cell='1arcsec' # cell size for imaging.
imsize = [128,128] # size of image in pixels.

When imaging lines, you will need to set two specific velocity parameters called outframe and veltype. Outframe is the coordinate system used for the observation. If you have access to the original proposal, this can be found in the Observing Tool (OT) under field setup. A list of acceptable outframes that can be used in CASA can be found at https://help.almascience.org/kb/articles/what-are-the-frequency-reference-frames-in-casa. Note: heliocentric(hel) is deprecated in CASA. Use barycentric(bary) in this case. The most common choices are 'bary' and 'lsrk'. Usually 'bary' is used for sources where z>0.2 ('extragalactic") and 'lsrk is used for 'galactic' sources. For ephemeris objects, the outframe should be set to a blank string, for example outframe = '', as you have likely already regridded to the source velocity in cvel() or can allow tclean to do it on the fly.

You will also have to set the veltype for the tclean command. This variable has only two options available, radio and optical. Due to an interaction between the ALMA Observing Tool and CASA, set the veltype to radio. Even if the object has an optically defined velocity, the sensitivity calculation uses the radio definition. This will avoid confusion in comparing the achieved sensitivity to the expected sensitivity.

# in CASA
outframe='lsrk' # velocity reference frame. See science goals.
veltype='radio' # velocity type.

The last four parameters that must be set are associated with how tclean will weight and clean the data. During the imaging process, the individual visibilities are placed on a uv grid and then combined. Weighting determines how tclean will combine the uv gridded to produce an image. There are several weighting schemes that can be used:

  • Natural: Each cell in the uv plane is weighted by the number of points in the cell. This weighting scheme is the default in tclean. It results in a lower noise image at the expense of worse angular resolution.
  • Uniform: Each cell in the uv plane has the same weight. In this case, the sidelobes will be reduced because the imaging plane is filled in more uniformly. This weighting scheme also gives more weight to longer baselines resulting in higher resolution at the expense of higher noise. It can emphasize visibilities with calibration errors.
  • Briggs: This weighting scheme is a combination of natural and uniform weighting. The weighting is controlled by the robust parameter. A robust parameter of 2 gives natural weighting, -2 uniform weighting, and a number in between a combination of natural and uniform. Refer to Brigg's Thesis for more information. Currently, robust is set to 0.5, which gives a good compromise between natural and uniform weighting. You may find, after imaging, that you have to decrease the noise or angular resolution based on the science goals. Playing with the robust parameter can affect your final noise in the image and also the angular resolution. If you are making a mosaic image do not use a robust value smaller than 0 as this may introduce major artifacts in the images including uneven noise across the image. If you choose to do any form of uvtapering to the data in tclean(), set robust to 2 (Natural weighting) to avoid upweighting points that are going to be downweighted by uv-taper.

The parameters niter and threshold provide two ways to stop the tclean process. The niter parameter is the maximum number of iterations allowed. After this limit has been reached, tclean will terminate. The threshold parameter sets a flux density threshold for the tclean. When the peak residual is below this value, tclean terminates. When cleaning interactively, we recommend setting the niter parameter to a large(say 1000), but not too large value (say 10000 or 100000) so that tclean terminates eventually in the case of human error. The threshold can be left at the default of 0.0mJy for interactive tclean. For non-interactive tclean, the recommendation is to set the threshold to several times the noise in the final image. To determine the threshold for cube images, run tclean with niter set to zero and inspect the resulting image in the viewer. In a line-free channel, select a region and look at the statistics panel to determine the noise level. For more detailed instructions, see the “Image the Spectral Line Data” section of EVLA Spectral Line Imaging Analysis IRC+10216.

# in CASA
weighting = 'briggs'
robust=0.5
niter=1000
threshold = '0.0mJy'

For more information on the various options available in tclean, refer to David Wilner’s Imaging and Deconvolution presentation from the 2016 Synthesis Imaging Workshop. The table below provides helpful pointers to relevant slides.

Imaging Parameters
Pixel and Image Size Slides 40-41
Weighting Slides 42-48, 60-61
Deconvolution Algorithms Slides 50-53, 62

Imaging the Continuum

Figure 9: During interactive tclean, the GUI will show an initial dirty image. From this GUI, create the tclean mask.
Figure 10: After a mask is created, the green arrow will be illuminated. Press this to begin the first 100 iterations. Once cleaning is complete, press the red "X" to finish.
Figure 11: The final residual image.

Now that you have set all of the imaging parameters you will need in tclean, you can proceed to imaging the continuum. The First Look at Imaging CASAGuide gives an introduction to cleaning and imaging. You may also find the Automasking Guide useful in allowing tclean to generate the mask used for cleaning automatically.

We provide an abbreviated set of commands here. If you are imaging a mosaic, the phasecenter parameter should be set. Refer to the Image Parameters section of this guide for instructions on how to determine this for your project. Type “help tclean()” in CASA if you would like to explore the possible parameters of tclean. Specode=’mfs’ sets the spectral gridding type to multi-frequency synthesis and creates a continuum image. If you are imaging the aggregate continuum in Band 3 or 4 and have a fractional bandwidth larger than 10%, you should consider using multi-term multi-frequency synthesis (deconvolver='mtmfs' and nterms=2). This tclean mode accounts for spatial spectral index variations and especially important to include if you have a spatially resolved, high S/N source. For more information on multi-term multi-frequency synthesis, see Rau, U., & Cornwell, T.J. 2011, A&A, 532, AA71. Clean interactively as the threshold is set at 0 mJy. The mask parameter may also be added if you have an existing file. You can create a mask from the dirty image using the instructions at Create_a_Clean_Mask_from_Continuum_Image_or_Moment_Cube.

In CASA 5.4 and later, tclean calls with gridder = 'mosaic' have an additional parameter mosweight with a default of True. When mosweight = True, the gridder weights each field in the mosaic independently. The mosweight parameter is particularly important for mosaics with non-uniform sensitivity, with rectangular shapes, or when using more uniform values of robust Briggs weighting. For more information on mosweight, please see the tclean documentation.

# in CASA
contvis = 'calibrated_final_cont.ms'         
contimagename = 'calibrated_final_cont'
# in CASA
tclean(vis=contvis,
       imagename=contimagename,
       field=field,
       #  phasecenter=phasecenter, # uncomment if mosaic or imaging an ephemeris object
       #  mosweight=True, # uncomment if mosaic     
       specmode='mfs',
       deconvolver='hogbom', 
       # Uncomment the below to image with nterms>1. Use if fractional bandwidth is >10%.
       #deconvolver='mtmfs',
       #nterms=2,
       imsize = imsize, 
       cell= cell, 
       weighting = weighting,
       robust = robust,
       niter = niter, 
       threshold = threshold,
       interactive = True,
       gridder = gridder,
       pbcor = True,
       usepointing=False)

Figure 9 shows the tclean GUI that will appear. If no source is apparent, no cleaning should be done. Press the red “X” to complete the task. If a source is apparent, create a mask around it using the mouse. Once a mask is created, the green arrow will be illuminated and you can begin the first round of cleaning. Figure 10 shows what a mask would look like for our example source. The logger window gives you vital information on the progression of tclean. Once the cycle is complete, the residuals will appear in the GUI. You should continue to iterate until the region inside the mask matches the noise outside the mask. You may need multiple cycles depending on the complexity of the source. Figure 11 shows an example of when we chose to stop cleaning.

The red "X" will stop tclean where you are, the blue arrow will stop the interactive part of tclean, but continue to clean non-interactively until reaching the number of iterations requested (niter) or the flux density threshold (whichever comes first), and the green circle arrow will clean until it reaches the "iterations" parameter on the left side of the green area. These are the only safe exit buttons to use during tclean. DO NOT CTRL-C OR KILL TCLEAN WHILE IT IS RUNNING. If you do this, it is very likely that your ms will be corrupted.

The final continuum image.

After creating the continuum image, check the noise and resolution to make sure the results match the expected values. Use the ALMA Sensitivity Calculator to estimate the expected sensitivity.

For each image it creates, tclean generates several images with the name imagename+extension. If you re-run tclean with the same imagename, tclean will use the existing files as a starting point, continuing the tclean where you left off. To start completely from scratch, either change the imagename or delete all the files from the previous tclean run. Note that CASA retains some image information in memory, so to truly delete the images, you need to run the rmtables command. You will also want to remove datacolumns that were added by tclean with clearcal and delmod. See below for an example.

# in CASA
clearcal(contvis)
delmod(contvis)
for ext in ['.image','.mask','.model','.image.pbcor','.psf','.residual','.pb','.sumwt']:
    rmtables(contimagename+ext)

Once you are happy with your continuum image(s), you can continue to Self-Calibration Template or Spectral Line Imaging Template. If you do not wish to self-calibrate or create line cubes, continue with this guide to create primary beam corrected images and fits files.

Export the images

Use exportfits to create fits files of the *.flux and *.pbcor files.

# in CASA
import glob

myimages = glob.glob("*.pbcor")
for image in myimages:
    exportfits(imagename=image, fitsimage=image+'.fits',overwrite=True)

myimages = glob.glob("*.pb")
for image in myimages:
    exportfits(imagename=image, fitsimage=image+'.fits',overwrite=True)

Create Diagnostic PNGs

The First Look at Image Analysis guide gives an introduction to a variety of options to begin image analysis, including using immoments to create moment maps. The following commands create png files of the continuum image.

# in CASA
os.system("rm -rf *.png")
mycontimages = glob.glob("*mfs*manual.image")
for cimage in mycontimages:
    mymax=imstat(cimage)['max'][0]
    mymin=-0.1*mymax
    outimage = cimage+'.png'
    os.system('rm -rf '+outimage)
    imview(raster={'file':cimage,'range':[mymin,mymax]},out=outimage)

Return to the Main Page