VLA CASA Pipeline-CASA4.5.3

From CASA Guides
Jump to navigationJump to search

This guide is designed for CASA 4.5.3


Introduction

When VLA observations are complete, the raw data need to be calibrated for scientific applications. This is achieved through various steps, as explained in the VLA CASA tutorials. The different calibration procedures are also bundled in a general VLA calibration pipeline that is described on the VLA pipeline webpage. At NRAO, the pipeline is now executed on every science scheduling block (SB) that the VLA observes. At this time, scientific target imaging is not part of the VLA pipeline. Manual imaging steps, however, are explained in the VLA CASA tutorials.

There are currently two maintained versions of the VLA pipeline: A calibration pipeline integrated in CASA, and an external, scripted pipeline. This VLA pipeline CASA tutorial guides through the version that is integrated in CASA. It is developed along with the ALMA pipeline and aims to use similar procedures and outputs (documentation for ALMA is available through the almascience.org portal/Documents & Tools. Details on the scripted pipeline can be found on the VLA scripted pipeline webpage.

The VLA pipeline has been developed to work for data taken in all 1-50GHz VLA frequency bands and requires minimal manual intervention. All calibration steps are applied to all data; this implies that simplicity and robustness currently has priority over speed. Pipeline runs can take anywhere from a few hours to several days, with a typical VLA SB being processed within the time span of about a day.

The pipeline was introduced in May 2012 and usually works well for all data taken thereafter. It may not work without modifications for data taken earlier and for such observations we recommend adjusting the scripted pipeline or to perform the calibration steps manually.


Pipeline Requirements

The VLA pipeline has been developed for Stokes I continuum data with a range of spectral windows (spws) that are typically 128MHz wide. Nevertheless, it usually also performs well on other setups, although it is currently not tailored for special needs. In the future, we will provide a reprocessing interface that allows the user to adapt the pipeline to the specifics of their observations including spectral line, and polarization. In the following we will also explain how to adapt the pipeline, e.g. for spectral line setups.

The pipeline relies on the correct setting of the scan intents. We therefore recommend every observer ensures that the scan intents are correctly specified in the Observation Preparation Tool (OPT) during the preparation of the observing script (see OPT manual for details). In particular, the pipeline requires the intents CALIBRATE_FLUX to mark flux density calibration scans (toward one of the standard VLA calibrators 3C48, 3C138, 3C147, or 3C286), CALIBRATE_AMPLI and CALIBRATE_PHASE for the temporal complex gain/phase calibration, and CALIBRATE_BANDPASS for the scan that is being used to obtain the bandpass calibration. CALIBRATE_DELAY marks the delay calibrator scan. If CALIBRATE_DELAY is not being set, delay calibration will use the scans with a CALIBRATE_BANDPASS intent. And bandpass (and as a third option delay) calibration will use the CALIBRATE_FLUX scans if CALIBRATE_BANDPASS is absent. The pipeline also currently requires a signal-to noise of >~3 for each spectral window of a calibrator per integration (for each channel of the bandpass).


Pipeline Execution

NRAO-Initiated Automatic Pipeline Runs

Every science schedule block (SB) executed at the VLA will be batch pipeline processed. NRAO uses a pipeline version that is packaged with CASA and that is also available to outside users (see the CASA download page for the current (and older) pipeline versions). At NRAO, we will always execute the standard pipeline, which implies that it is optimized for Stokes I continuum processing independent of the actual observation setup. A user may therefore decide to run the pipeline after making appropriate modifications.

Once an SB has been processed, the PI of the project will receive an email that pipeline calibrated data are available and can be requested via the NRAO helpdesk. For ~15 days, the calibrated MeasurementSet (MS) will be stored for download. After that period, we delete the calibrated MS but retain the calibration and flagging tables and the weblog. The user may then request these products and apply them to the raw MS (downloaded from the archive) to obtain calibrated visibilities (see the VLA pipeline webpage for more details).

The user should inspect the weblog and the calibrated data from the VLA pipeline results carefully. Usually, some additional flagging and reprocessing will be required for better results. Upon request through the NRAO helpdesk a member of the staff can perform a detailed quality assessment of the pipeline results.

Starting the Pipeline Manually

Pipeline processing can be quite computing intensive. On the CASA Hardware Requirements page, we provide some recommendations for a suitable computing infrastructure. If you would like to use the NRAO lustre/cluster system, please request an account through the NRAO helpdesk.

The VLA pipeline webpage provides details on how to execute the VLA pipeline. To start with, a CASA version with integrated pipeline heuristic code is required and can be downloaded from the CASA webpages.

We also recommend to download the VLA raw data from the NRAO archive in the form of a 'Science Data Model-Binary Data Format' (SDM-BDF), the raw VLA archive data format (although MeasurementSets may also work).

If you want to run the pipeline for the data that is shown in this giude, search the NRAO archive for the file id: 13A-398.sb17165245.eb19476558.56374.213876608796

To include the pipeline heuristic tasks, start CASA with the --pipeline option:

# In a Terminal
casa --pipeline

At NRAO one can start the current default pipeline version via:

# In a Terminal
casa-pipe

Next, at the CASA prompt, import the VLA pipeline recipes like:

# In CASA
import pipeline.recipes.hifv as hifv


The actual execution of the pipeline on the SDM, in our example 13A-398.sb17165245.eb19476558.56374.213876608796, will be initiated like:

# In CASA
hifv.hifv(['13A-398.sb17165245.eb19476558.56374.213876608796'])

The pipeline will now start processing the data. Depending on the data size and structure, processing times range somewhere between a few hours and several days.

Pipeline Output

VLA pipeline output includes:

  • An MS with calibrated visibilities in the CORRECTED_DATA column that can be used for subsequent imaging (in the root directory of the pipeline run).
  • Calibrator images for all spws (files oussid* in the root directory; see the descriptions of the tasks hifv_makeimlist and hifv_makeimages below).
  • All calibration tables and the MS.flagversions' directory that contains various flag backups made at various stages of the the pipeline run (root directory).
  • A weblog that is accessible via pipelineXXXX/html/index.html, where the XXX stands for the pipeline execution time stamp (multiple pipeline executions will result in multiple weblogs).
  • The casapyXXX.log CASA logger messages (in pipelineXXXX/html/).
  • casa_pipescript.py (in pipelineXXXX/html/), the script with the actually executed pipeline heuristic sequence and parameter (see below).
  • casa_commands.log (in pipelineXXXX/html/), which contains the actual CASA commands that were generated by the pipeline heuristics (see below).
  • The listobs output is available under pipelineXXXX/html/sessionSession_default/<MSname>.listobs.txt' 'and contains the characteristics of the observations (temporal, spatial, spectral setup, antenna positions, and general information).


Calibration Tables

The final calibration tables of the pipeline are (where <SDM> is a placeholder for the SDM name):

<SDM>.ms.hifv_priorcals.s5_3.gc.tbl : Gaincurve
<SDM>.ms.hifv_priorcals.s5_4.opac.tbl : Opacity
<SDM>.ms.hifv_priorcals.s5_5.rq.tbl : Requantizer gains
<SDM>.ms.hifv_priorcals.s5_6.ants.tbl : Antenna position offsets
<SDM>.ms.finaldelay.k : Delay
<SDM>.ms.finalBPcal.b : Bandpass
<SDM>.ms.averagephasegain.g : Temporal Phase offsets
<SDM>.ms.finalampgaincal.g : Flux calibrated Temporal Gains 
<SDM>.ms.finalphasegaincal.g : Temporal Phases


casa_pipescript.py

VLA pipeline heuristic tasks start with hifv for 'heuristics, interferometry, vla'. The pipeline sequence of the pipeline heuristic steps are listed in the 'casa_pipescript.py' that is located in the 'pipelineXXXX/html' directory. For our example, 'casa_pipescript.py' has the following structure:

__rethrow_casa_exceptions = True
h_init()
 try:
    hifv_importdata(ocorr_mode='co', vis=['13A-398.sb17165245.eb19476558.56374.213876608796'], createmms='automatic', asis='Receiver CalAtmosphere', overwrite=True)
    hifv_hanning(pipelinemode="automatic")
    hifv_flagdata(intents='*POINTING*,*FOCUS*,*ATMOSPHERE*,*SIDEBAND_RATIO*, *UNKNOWN*, *SYSTEM_CONFIGURATION*, *UNSPECIFIED#UNSPECIFIED*', flagbackup=False, scan=True, baseband=True, clip=True, autocorr=True, hm_tbuff='1.5int', template=False, online=True, tbuff=0.0, fracspw=0.05, shadow=True, quack=True, edgespw=True)
    hifv_vlasetjy(fluxdensity=-1, scalebychan=True, reffreq='1GHz', spix=0)
    hifv_priorcals(pipelinemode="automatic")
    hifv_testBPdcals(pipelinemode="automatic")
    hifv_flagbaddef(pipelinemode="automatic")
    hifv_checkflag(pipelinemode="automatic")
    hifv_semiFinalBPdcals(pipelinemode="automatic")
    hifv_checkflag(checkflagmode='semi')
    hifv_semiFinalBPdcals(pipelinemode="automatic")
    hifv_solint(pipelinemode="automatic")
    hifv_fluxboot(pipelinemode="automatic")
    hifv_finalcals(pipelinemode="automatic")
    hifv_applycals(pipelinemode="automatic")
    hifv_targetflag(pipelinemode="automatic")
    hifv_statwt(pipelinemode="automatic")
    hifv_plotsummary(pipelinemode="automatic")
    hif_makeimlist(nchan=-1, calmaxpix=300, intent='PHASE,BANDPASS')
    hif_makeimages(masklimit=4, noise='1.0Jy', subcontms=False, target_list={}, parallel='automatic', maxncleans=1, weighting='briggs', tlimit=2.0, robust=-999.0, npixels=0)
finally:
   h_save()

This is in fact a standard casa_pipescript.py file that can be used for pipeline processing in general after inserting the correct filename in hifv_importdata. (But note that executions at NRAO may show small differences, e.g. a final hif_exportdata step that packages the products to be stored in the NRAO archive.)

The pipeline run can be modified by adapting this script, e.g. by commenting out individual steps or by providing different parameters (see the inline help for the parameters of each task). The script can then be (re-)executed via:

# In CASA
execfile('casa_pipescript.py')

We will use this method, e.g. to modify the script after being adjusted for spectral line processing (see below).

General modifications to the script include setting __rethrow_casa_exceptions = False to suppress CASA error messages in the weblog and h_init(weblog=False) for speedy processing without any weblog or plotting.


casa_commands.log

'casa_commands.log' is a second useful file in 'pipelineXXXX/html', which lists all the CASA commands that the pipeline heuristics (hifv) tasks produced. Note that 'casa_commands.log' is not executable itself, but it contains all the CASA tasks and associated parameters to trace back the individual data reduction steps.


The Pipeline Weblog

The pipeline run can be inspected through a weblog that is launched by pointing a web browser to 'pipelineXXX/html/index.html' (wher XXX is the timestamp of the execution).

The following discussion is based on a weblog that can be obtained through the following link:

https://casa.nrao.edu/Data/EVLA/Pipeline/VLApipe-guide-weblog.tar.gz (209 MB) 

Extract the weblog via:

# In a Terminal
tar xzvf VLApipe-guide-weblog.tar.gz

and point your browser to html/index.html.

At the top of the landing page Home (this page), By Topic and By Task provide navigation through the pipeline results.

Home Screen

The Home page of the weblog (Fig. 1) contains essential information such as the project archive code, the PI name, and the the start and end time of the observations. The CASA and pipeline versions that were used for the pipeline run are also listed on this page, as well as a table with the MS name, receiver bands, number of antennas, on source time, min/max baseline lengths, the atmospheric phase monitor rms, and the filesize.

Fig. 1: The main page of the weblog

Overview Screen

An overview of the observations (Fig. 2) can be obtained by clicking on the MS name.

Fig. 2: The weblog overview page.


This page provides additional information about the observation. That includes Spatial Setup (field names, target and calibrator names), Antenna Setup (min/max baseline lengths), Spectral Setup (band designations; science bands include most calibrators but exclude ancillary scans such as pointing scans), and Sky Setup (min/max elevation). The page also provides graphical overviews of the scan intent and field id observing sequence. A plot with weather information is also provided. Clicking the blue headers provides additional information on each topic.

Fig. 3: Spatial Set page.

The Spatial Setup page (Fig. 3) lists all sources and fields (where a source is a field with a given spectral setup). Names, IDs, positions, and scan intents are listed for each source/field.

Fig. 4a: Antenna Setup page (Antennas).
Fig. 4b: Antenna Setup page (Baselines).

The Antenna Setup (Fig. 4) page lists the locations of all antennas (antenna pad name and offset from array center) and contains a graphical location plot for the array configuration. On a second tab, baseline lengths are being listed and the 'percentile' column provides a rough indication of their density.

Fig. 5: Spectral Setup page.

The Spectral Setup page (Fig. 5) contains all spectral window descriptions, including start, center and end frequencies, the bandwidth of each spw, as well as the number of spectral channels and their widths in frequency and velocity units. For each spw the polarization products and the receiver bands are listed, too. Note that Science Windows contain all spws that are used for calibration. Setup and pointing scans are not part of science windows but they are available under All Windows together with their intents.

Fig. 6: Sky Setup page.

Clicking the Sky Setup page (Fig. 6) leads to elevation vs Azimuth and Elevation vs Time plots for the entire observation. The plots are colorized by field and intent.

Fig. 7: Scans page.

Scans (Fig. 7) provides a listing of all scans, including start and stop time stamps, durations, field names and intents, and the tuning (spw) setup for each. Again Science Scans and All Scans can be inspected in separate tabs.

Most of the above information can also be accessed by the 'LISTOBS OUTPUT' button. The link leads to the results of the listobs task, which includes the execution of the observational setup details of the MS (Fig. 8), including the scan characteristics, with execution times, scan ids, field ids and names, associated spectral windows, integration times, and scan intents. Further down, the spectral window characteristics are provided through their ids, channel numbers, channel widths, start and central frequencies. Sources and antenna locations are part of the listobs output, too.

Fig. 8: The listobs output.

By Topic Screen

The top-level By Topic link leads to a page that provides basic pipeline summaries such as warnings, scores (the scores are not implemented as of CASA 4.5.3 and should be considered placeholders for future implementation) and flagging summaries as functions of field, antenna, and spw (Fig. 9).


Fig. 9: The By Topic page of the weblog.

By Task Screen: Overview of the Pipeline Heuristic Stages

The pipeline is divided into 20 individual pipeline heuristic stages with heuristic ('hifv') tasks listed under the By Task tab (Fig. 10). Each stage has an associated score for success, but note that the scores are not yet implemented as of the CASA 4.5.3 VLA pipeline (C3R4B). Warnings and errors in tasks are indicated by 'exclamation mark' and 'cross' icons near the task names. In our example, the pipeline threw warnings during stages 1 and 20, and an error in stage 4.

Fig. 10: The By Task pipeline execution stages.

To obtain more details on each stage, click on the individual task names. Task sub-pages contain task results such as plots or derived numbers. Common to all pages is information on the (Pipeline QA; 'Quality Assurance', not implemented in the CASA VLA pipeline as packaged in 4.5.3), the heuristic task Input Parameters, Task Execution Statistics (benchmarks), and the CASA logs, which provide details on the heuristic output and the provides the actual CASA task executions and their return logger messages.


The Individual Stages

Stage 1. hifv_importdata: Register VLA measurement sets with the pipeline

In the first stage, the raw SDM-BDF is imported to a CASA MS. Basic information on the MS is being provided, such as SchedBlock ID, the number of scans and fields and the size of the MS. The MS is also being checked for suitable scan intents and a baseline summary of the initial flags is calculated.

Fig. 11: The Stage 1 hifv_importdata task page.

In our example (Fig. 11), a warning is issued that the data does not contain a CALIBRATE_BANDPASS scan intent. In such a situation, the pipeline will use the flux density calibrator scans (marked by the CALIBRATE_FLUX intent) for bandpass calibration.

CHECK for: any errors in the import stage. That includes missing scan intents similar to our example. Warnings will also be issued if the data were previously being processed, this is usually encountered when the pipeline is run on an MS rather than an SDM.  

Stage 2. hifv_hanning: VLA Hanning Smoothing

This stage Hanning-smoothes the MS. This procedure will reduce the Gibbs phenomenon (ringing) when extremely bright and narrow spectral features are present spill over into adjacent spectral channels. Gibbs ringing is typically caused by strong RFI. As part of the process, Hanning smoothing will reduce the spectral resolution.

CHECK for: nothing except for completion of the task. FOR SPECTRAL LINE DATA: you may decide not to run this stage since spectral lines will be smoothed to a degraded spectral resolution (see section on spectral line processing).

Stage 3. hifv_flagdata: VLA Deterministic flagging

This stage will apply flags that were generated by the VLA online system during the observations. They include antennas not on source (ANOS), scans with intents that are of no use for the pipeline such as pointing and focus scans, autocorrelations, the first and last 5% edge channels of each spw (with a minimum of 3), clipping absolute zero values that the correlator occasionally produces, quacking (ie flagging start or end integrations of scans; the pipeline wil flag the first 1.5 integrations after a source change), and flagging of entire basebands if needed. The flags are reported as a fraction of the total data for the full dataset as well as broken up into the individual calibrator scans and target data. A plot is provided that displays the online antenna flags as a function of time.

Fig. 12: The Stage 3 hifv_flagdata task page.

In our example (Fig. 12), the target source starts with 3.12% flagged data, the deterministic flagging stage adds 6.05% for to antenna not on source, 0.82% of other online flags (e.g. subreflectors rotations or translations), edge channels amount to 6.4%, clipping of absolute zero values to 0.09%, and 1.40% of flags are due to baseband clipping. This combines to a total of 8.71% of flagged data for the scientific target. Other sources are also listed and the entire MS is being flagged on a 8.84% level.

CHECK for: the percentage of the flags. If a very large portion (or even all) of the visibilities of the calibrators are flagged, try to find out the reason. Also have a quick look at the graph of the online flags to understand whether the system behaved normally or if there was an unusually high failure of some kind.

Stage 4. hifv_setjy: Set calibrator model visibilities

Stage number 4 calculates and sets the calibrator spectral and spatial model for the standard VLA flux density calibrators (3C48, 3C138, 3C147, or 3C286 with a CALIBRATE_FLUX scan intent). The task page lists the calculated flux densities for each spw. It also contains plots of the amplitude vs. uv-distance for the models per spw that are calculated and used to specify the flux density calibrator characteristics.

Fig. 13: The Stage 4 hifv_setjy task page.

In our case, hifv_setjy throws an error (QA Too many flux calibrator measurements for 13A-398.sb17165245.eb19476558.56374.213876608796.ms 66/64; Fig. 13), which is due to the inclusion of pointing scans that are later disregarded. This is nothing to worry here as the X-band pointing scans are not being used for any scientific application. Pointing corrections are being calculated and applied in the online system at the time of observation and are not being used thereafter.

CHECK for: any unexpected flux densities or model shapes.

Stage 5. hifv_priorcals: Priorcals (gaincurves, opacities, antenna positions corrections and rq gains)

Next, the prior calibration tables are being derived. They include gain-elevation dependencies, atmospheric opacity corrections, antenna offset corrections, and requantizer gains. They are independent of the calibrator observations themselves and can be derived from ancillary data such as antenna offset tables, weather data, antenna elevation, and switched power measurements.

Fig. 14a: The Stage 5 hifv_priorcals task page.
Fig. 14b: The Stage 5 hifv_priorcals task page.

In addition to the opacities themselves (calculated per spw; Fig. 14), a plot is attached that provides more information on the weather conditions during the observation. The antenna positions are usually updated a few days after an antenna was moved, and for our case corrections for four antennas are being applied with offsets in the millimeter range.

CHECK for: extreme or unrealistic opacities. Also check that the antenna offsets are within reason. There should only be updates for a few antennas.

Stage 6. hifv_testBPdcals: Initial test calibrations

Now it is time to determine the delays, and the bandpass solution (gain and phase) for the first time. Applying the initial solution will make it easier to identify RFI to be flagged. There will be a couple of iterations for the calibration tables along this method in the following pipeline stages to eventually obtain the final set of calibration tables.

Fig. 15: The Stage 6 hifv_testBPdcals task page.

The plot on the main page (Fig. 15) shows the bandpass calibrator with the initial bandpass solution applied. The subpages show the delay, gain amplitude, gain phase, bandpass amplitude, and bandpass phase solutions for each antenna. Note that the phases will be close to zero for a single reference antenna (we will later see an example where a few antennas are being used for reference. This will show up as steps in the phase plots. When delays are more than +/-10ns it will be worth examining the data more closely. Some additional flagging may be needed.

The gain amplitude and phase solutions are derived per integration and they are used to correct for decorrelation before any spectral bandpass solutions are calculated. The latter are determined over a full solution interval, usually for all bandpass scans together. Bandpasses should be smooth although they can vary substantially over wide frequency bands. The BP phases should capture the residuals after the delays were calibrated.

Fig. 16a: Delays for ea16.
Fig. 16b: Delays for ea21.
Fig. 16c: Delays for ea22.

Example delays are shown in Fig. 16: The delay for ea16 varies but is within a narrow range of only a few ns. These are good solutions. The delays for ea21 are fine except for the 33-35GHz frequency range where they scatter substantially. The respective frequency range/spws should be flagged manually if the following pipeline steps will not take care of it. For ea22 the delays in the 35-37GHz range are excessive with a value of about -70ns. It is likely that the pipeline will be able to calibrate these values correctly but one may need to flag the respective spws if not.

Fig. 17a: Gain Amplitude for ea03.
Fig. 17b: Gain Amplitude for ea04.
Fig. 17c: Gain Amplitude for ea18.
Fig. 17d: Gain Amplitude for ea25.

In Fig. 17, we show some of gain amplitude plot examples. Ea03 shows perfect solutions (the colors represent different spws and polarizations and a flux spread as a function of frequency is expected), whereas ea04 has elevated values until 8:06. Those should be flagged (but the pipeline may be able to detect and flag them in one of the subsequent stages). Some of the baselines in ea18 show low values in the 2-3Jy range, but they are constant in time. At this stage one can assume that they reflect the correct calibration values. It might still be worth to make a note and check if calibration downstream was applied correctly. The situation is different for ea25 which shows an extreme decrease of flux as a function of time. This is likely a tracking error (possibly caused by the subreflector) where the source sits near the edge of the HPBW, a HPBW that varies with frequency. It is likely that the primary beam sensitivity thus creates the spread and the associated tracking error causes the flux changes. This antenna should be inspected carefully, there could be a problem which will make it unusable. Although the bandpass solutions seem to be ok, the bandpass and flux calibrators coincide and it is likely that the absolute flux density calibration is very unreliable for this antenna.

Fig. 18a: Gain Phase for ea09.
Fig. 18b: Gain Phase for ea03.
Fig. 18c: Gain Phase for ea21.

Since the gain amp/phase steps pre integration are only performed to reduce decorrelation, the phase plots are the most important in this context. In Fig. 18 we show a few solutions. All phases for the reference antenna ea09 are by definition zero. The phase variations as a function of time increase for higher frequencies and longer baselines. Therefore both, ea03 and ea21 have good solutions given that ea03 is closer to ea09 than ea21 (cf. the Antenna Setup on the Overview page). There are no jumps in the phases - remember that -180 and +180 are identical phase values and connectors between those values are only a plotting issue, not the actual phase behavior.

Fig. 19a: BP Gain for ea17.
Fig. 19b: BP Gain for ea18.
Fig. 19c: BP Gain for ea21.
Fig. 19d: BP Gain for ea24.
Fig. 19e: BP Gain for ea25.

Now let's have a look at the bandpasses themselves (Fig. 19). Ea17 shows very good bandpass solutions. Since the spws are small compared to the entire frequency range, the edges of each spw dominate the variations. The 37-39GHz range of ea18 varies considerably more. In fact this antenna, polarization and baseband shows a deformatter timing error (more in the following stage 7) which needs to be flagged. Some flagging was already performed for the 33-35GHz range of ea21. This range corresponds to the noisy delays that we saw earlier in Fig. 16b. Ea24 shows a few high values. They usually are fine as they also correspond to the edges of the spws. In particular if an spw edge coincides with a baseband edge, such spikes are usually more pronounced. Keep an eye on those although they are likely not a problem for the calibration. Finally, we show the bandpass of ea25, the antenna with the likely tracking error. Although the Gain Amplitude showed decreasing values as a function of time (Fig. 17d), the bandpass itself does not look suspicious and can likely be used, based on this plot. The tracking error, however, may also be present for other scans and since we identified it first for a flux density calibrator scan, that antenna should be flagged.


Fig. 20a: BP Phase for ea09.
Fig. 20b: BP Phase for ea11.
Fig. 20c: BP Phase for ea18.
Fig. 20d: BP Phase for ea24.

The BP phases (Fig. 20) show residual, channel by channel delays. Again the reference antenna ea09 only shows zero phases by definition. Ea11 is an example of perfect phases across the bandpass. Note that again that the variations are dominated by residual phases at the edges of the spws. Some variations are larger than others, but they are all in a similar range. We already saw the large scatter in the bandpass amplitude of ea18 at 37-39GHz due to a bad deformatter and the pattern is repeated in the phases. Finally we show ea24 again and find that the edge spike in the amplitudes is also seen in the phases. At this level, the solution should be usable.

CHECK for: strong RFI and whether it was eliminated in later flagging stages or not (especially via a comparison with the output plots of task 14). Also check for jumps in phase and or amplitude away from spw edges. If there are phase jumps for all but the reference antenna, maybe a different choice for the reference antenna should be considered. Also watch out for extreme delays of tens of ns and for very noisy data. 

Stage 7. hifv_flagbaddef: Flag bad deformatters

The data inside every VLA telescope is undergoing a formatting stage to convert the electronic to an optical signal before it is injected on the optical fiber link. On the correlator end the signal will be deformatted back to an electronic signal. Occasionally, the timing on the deformatter can be misaligned which results in very strong amplitude or phase slopes as a function of frequency. Sometimes the signal is similar to an abs(sin), or a 'bouncing' signal across a baseband for one polarization. The hifv_flagbaddef pipeline stage tries to identify such deformatter errors by checking for deviations more than 15% over the average bandpass. In that case the antenna, polarization, and spw are being flagged. If more than 4 spws of a baseband are affected this way, the entire baseband will be flagged.

Fig. 21: The Stage 7 hifv_flagbaddef task page.

For our data, no deformatter issues were automatically detected in the data for the amplitudes but the phases of a few spws are being flagged (Fig. 21). We did see, however, that ea18 has a deformatter problem in the 37-39GHz baseband (Figs. 19b/22a and 20c). Since this stage 7 did not detect and flag this range (which shows the limitations of the underlying code), manually flagging will be required for the affected antenna, polarization, and baseband for all sources. An example from a different dataset is provided in Fig. 22b. The 'V' shape close to 5.3GHz with values close to zero are a tell-tale sign for a deformatter problem.

Fig. 22a: Same as 19b, ea18 which shows a digital trasmission issue that hifv_flagbaddef was not able to identify.
Fig. 22b: An example for a bad deformatter from a different dataset.
CHECK for: amplitude 'bounces', i.e. very strong variations of amplitude and/or phase well above the average of the other polarizations or basebands. The pattern can repeat a few times across a baseband but should be contained to a single baseband, antenna and polarization. All spws in a faulty baseband, however, are affected. 

Stage 8. hifv_checkflag: Flag possible RFI on BP calibrator using rflag

Rflag as part of flagdata is a threshold-based automatic flagging algorithm in CASA. In this step, rflag is being run on the bandpass calibrator to remove relatively bright RFI and to obtain improved bandpass calibrations tables later on.

CHECK for: nothing in particular on this page, but some cumbersome RFI may have been eliminated in preparation for the following steps.

Stage 9. hifv_semiFinalBPdcals: Semi-final delay and bandpass calibrations

Now that some RFI was flagged, stage 6 is being repeated here at stage 9, which results in better bandpass and delay solutions.

CHECK for:  similar issues as in step 6.

Stage 10. hifv_checkflag: Flag possible RFI on BP calibrator using rflag

Once more rflag is being executed. After the bright RFI has been removed in step 8 and a new bandpass solution has been applied in step 9, a new mean data threshold will account for weaker RFI, which will be removed in this step 10.

CHECK for: removal of RFI seen in the following steps.

Stage 11. hifv_semiFinalBPdcals: Semi-final delay and bandpass calibrations

Again, having removed more RFI, new delay and bandpass solutions are being obtained here.

CHECK for: similar to step 6.

Stage 12. hifv_solint: Determine solint and Test gain calibrations

For the final calibration, the pipeline determines the shortest and longest applicable solution interval (solint). Typically they refer to the length of the longest integration and a scan, respectively.

Fig. 23: The Stage 12 hifv_solint task page.

In our case (Fig. 23) the longest time per integration is 3 seconds which therefore also corresponds the shortest solution interval. The longest solution interval is based on the longest phase calibrator scan, which lasts for ~85s; minus the drive time and 'quack' flagging the longest solution interval results in ~75s.

Fig. 24a: Gain vs. Time for ea03.
Fig. 24b: Gain vs. Time for ea04.
Fig. 24c: Gain vs. Time for ea25.

Using these solution intervals, a temporal gain and phase solution is calculated for each antenna, spw, and polarization. In Fig. 24 we show some examples for the gains. Ea03 shows perfect gain solutions with small variations over the time of the observations. Note that the last scan is the flux density calibrator and thus a different source with a different flux and gain. Ea04 shows increased values for the last few calibrator scans that may need to be flagged. Ea25 has likely a pointing error that deteriorates over the first half of the observations. The listobs output tells us that a pointing update was obtained around 6:40 at which point ea25 indeed recovered and shows good solutions.

Fig. 25a: Phase vs. Time for ea03.
Fig. 25b: Phase vs. Time for ea04.
Fig. 25c: Phase vs. Time for ea09.

Although the phase solution plots are very crowded (Fig. 25), we can see that ea03 has very steady values over time. The pipeline will apply phase offsets that are determined from this solution, so later on, additional phase solutions will be close to zero. Ea04 shows larger variations. Ea09 is the initial phase reference antenna. The underlying gaincal command, however, was given a few possible reference antennas, ea09, ea14, ea13, ea03, in case a single reference is not usable for all times and spectral windows. Check the CASA log for stage 12 at the bottom for the actual command. Indeed gaincal decided to chose different reference antennas for the solutions as the CASA log reports. To keep the phase interpolation consistent, ea09 phases have to absorb the offsets introduced by the alternate reference antennas. This explains the plot that we see here.

CHECK for: consistency with the data. The shortest solution interval should be close to the longest integration time and the longest to a calibration scan. Gains should be smooth with little variations in time (larger gain variations for higher frequencies), phases should not show any jumps and be relatively smooth in time (larger phase variations for higher frequencies and longer baselines).

Stage 13. hifv_fluxboot: Gain table for flux density bootstrapping

Now, the fluxes are bootstrapped from the flux density calibrator to the complex gain (gain and phase) calibrator. To do so, spectral indices are computed for the secondary calibrator and the absolute fluxes are determined for each channel. They are then set to the MODEL column via setjy and reported for each spw.

Fig. 26: The Stage 13 hifv_fluxboot task page.

For our example, the pipeline derives fluxes between 0.61 and 0.68 Jy for the phase calibrator, depending on frequency. The spectral behavior is reported as a declining spectral index of around -0.5 (Fig. 26).

CHECK for: that the values are close to the known fluxes of the calibrator. Check the VLA calibrator manual at https://science.nrao.edu/facilities/vla/observing/callist for consistency. Since most calibrator sources are time variable AGN, some differences to the VLA catalog are expected. In particular at higher frequencies they could be up to tens of per cent.

Stage 14. hifv_finalcals: Final Calibration Tables

The final calibration tables are now being derived. Those are the most important ones as they are being applied to the data in the subsequent stage 15. The tables are (one for each antenna): Final delay plots, BP initial gain phase, BP Amp solution, BP Phase solution, Phase (short) gain solution, Final amp time cal, Final amp freq cal, and Final phase gain cal. We have already inspected and discussed similar plots for the bandpass and for the temporal gain/phase calibration earlier. But since these are the most important tables, let's have a closer look at a few more tables.

Fig. 27a: Temporal Gains for ea02.
Fig. 27b: Temporal Gains for ea04.
Fig. 27c: Temporal Gains for ea07.
Fig. 27d: Temporal Gains for ea09.
Fig. 27e: Temporal Gains for ea18.
Fig. 27f: Temporal Gains for ea23.
Fig. 27g: Temporal Gains for ea25.

The gains vary quite a bit for this observation. Typically, the gains stay within 10% around a normalized value of 1. Here, a few spws show substantial deviations. Examples are (Fig. 27): Ea02 has a drop around 5:50 and should be checked. Maybe the entire time between the adjacent calibrator scans, those that are more in line with the rest, may be flagged for this antenna. Ea04 has an inverse behavior later, around 8:00. It appears that only a subset, e.g. a baseband deviates from the rest. Ea07 is more smooth, with some variations between the individual spws but overall a smooth temporal behavior. Likely this solution can be used with no further flagging. Note that the last scan is the flux calibrator. This datum is expected to have slightly different values than those for the complex gain calibrator. Next, we look at the almost perfect ea09 gains. This is also the reference antenna. The gains in ea18 are smooth with a large dip in the first half. This is in fact does calibrate out some characteristics of the observations and could be left for the moment. As mentioned before, around 6:40, a pointing update was performed which seems to have rectified a possibly mis-pointed ea18. Ea23 requires a single spw at a single time to be flagged. The tracking errors that we have identified for the bandpass/flux calibrator scan of ea25 have transferred to its phase calibrator scans. That explains the amplitude spread of the spws. In addition, this antenna also has apointing error for the first half of the observation. We again recommend to flag the entire antenna.

Fig. 28a: Spectral Gains for ea02.
Fig. 28b: Spectral Gains for ea04.
Fig. 28c: Spectral Gains for ea08.
Fig. 28d: Spectral Gains for ea20.
Fig. 28e: Spectral Gains for ea25.

Now let's have a look at the gains as a function of frequency (Fig. 28). For ea02 we see that one line is below the rest. This is likely one specific time interval and indeed we have seen such a slip in Fig. 27a. Ea04 has a very noisy time interval, which is also in agreement with what we have seen in the previous temporal gain plot. Ea08 shows a perfect calibration and ea20 repeats the extra noise in the 34-35GHz range that may need to be flagged. Ea25 now repeats the bandpass pattern that we have seen earlier and that explains the spread in Fig. 27.


Fig. 29a: Temporal Phases for ea02.
Fig. 29b: Temporal Phases for ea04.
Fig. 29c: Temporal Phases for ea09.
Fig. 29d: Temporal Phases for ea13.
Fig. 29e: Temporal Phases for ea15.
Fig. 29f: Temporal Phases for ea17.
Fig. 29g: Temporal Phases for ea20.

The phases are shown in Fig. 29. Ea02 clearly shows very erratic gain variations for one baseband or polarization. This is likely not recoverable. The user may plot the solution in plotcal or plotms and locate the faulty spws or polarizations and flag them. Ea04, in contrast, exhibits very smooth phase variations until near the end of the observations. This has already been observed in the gains (Fig. 27b), should be looked at, and likely needs to be flagged. Ea09 is the reference antenna and zero in phase. Ea13 shows smooth variations and is an example for a perfect calibration table. A spread between basebands or polarizations can be seen for ea15. The behavior is nevertheless smooth and the data should be calibrated nicely with this table. Ea17, however, has, in addition to different behaviors for the basebands, also relatively large and erratic jumps between the calibration scans. This clearly needs to be looked into further and may require flagging, although the antenna did not show any issues in previous plots. Finally, ea20 has a relatively smooth behavior until the pointing update was performed (although the variations are relatively large). After the pointing scan, however, phases vary by about +/-50degree between individual, consecutive calibrator scans, which is large enough to be unreliable and to be flagged.

CHECK for: issues similar to those described in stages 6 and 12. Note that carefully checking calibrator tables in this stage 14 is of particular importance as they are the final tables that are applied to the target source. Phase (and gain) calibration solutions should be inspected in their temporal variations to be smooth and consistent for each calibrator.

Stage 15. hifv_applycals: Apply calibrations from context

The calibration itself now concludes with the application of the derived calibration tables to the entire dataset. That includes all calibrators as well as the target sources. Note that there's no system temperature weighting of the calibration tables for the VLA (calwt=F) since the switched power calibration is currently not being used.

Fig. 30a: The Stage 15 hifv_fluxboot task page.
Fig. 30b: The Stage 15 hifv_fluxboot task page.
Fig. 30c: The Stage 15 hifv_fluxboot task page.

In Fig. 30, we show the results of this step. The first table lists the tables that are being applied, the fields, spws, and antennas that are calibrated. The second table provides information on the flagging statistics. Failed calibration solutions result in flagged calibrator table entries and eventually the data will also be flagged as no calibration can be derived for such data. The following plots show the data of different calibrator sources and spws in different combinations of phase and amplitude against frequency and uv-distance. To start with, the amplitude and phase as a function of frequency are being plotted for each baseband of the complex gain/phase calibrator. Next, the amplitudes as a function of uv-distance are plotted for each spw of the flux calibrator. They are followed by amplitude/time plots for all sources. Finally the amplitudes and phases against time and amplitude against frequency are being plotted for each target source baseband.

Fig. 31a: Calibrated data where an spw near 34GHz has a drop in flux.
Fig. 31b: Phase vs. frequency.
Fig. 31c: The amplitude vs. uv-distance for the flux calibrator, spw=35.
Fig. 31d: The amplitude vs. time for spw=24.
Fig. 31f: Amplitude vs. frequency for a target field.

In Fig. 31 we show a few examples. a) An spw that drops in the calibrated spectrum indicates that it is mis-calibrated. b) Although the phases are well calibrated, residual delays are still visible. The zig-zag pattern is due to a small mismatch in the delay measurement timing (aka. 'delay clunking'). This behavior is intrinsic to the VLA. Typically the effect is averaged out over time. c) Any amplitude vs. uv-distance plot for the flux calibrator should show a flat behavior for each spw (uv radial dependencies are taken into account for by the setjy model). The offset may indicate one antenna or one time to be offset from the others. This should be inspected further. d) Amplitude vs. frequency for a calibrator shows a baseline or time that should be investigated and may need additional flagging. For the target source (e) the data is usually noisy and systematic issues are difficult to identify.

CHECK for: a smooth amplitude vs. frequency plot. Jumps may indicate mis-calibrated bandpass fluxes for a spw. Also the shape of the individual spws should be largely removed. Check for deviations from a flat amplitude vs. uv-distance plot after the model was applied as it could indicate badly calibrated times or antennas.

Stage 16. hifv_targetflag: Targetflag

After the calibration tables are applied, the automated flagging routing rflag is run one more time on all sources to remove RFI and other outliers from the data.

CHECK for: RFI removal in the target. Although flagging is performed for all fields, the calibration is applied in a previous stage and any additional flags have no more influence on the calibration tables. Flagging may, however, improve all images that are being made in the following stages. In particular the target fields are flagged here for the first time whcih will benefit their image quality. FOR SPECTRAL LINE DATA: do not run this step as spectral lines may be removed, too (see also below).

Stage 17. hifv_statwt: Reweight visibilities

Since the VLA pipeline is currently not using the switched power calibration, there can be some sensitivity variations of the data over time due to changes in opacity, elevation, temperature (gradients) of the antennas, etc. So it is usually advisable to weigh the data according to the inverse of their noise. This is done via the CASA task statwt and will increase the signal-to noise ratio of images. Note that features such as RFI spikes and spectral lines will be part of the rms calculations and usually results in down-weighting data that includes such features.

CHECK for: improved signal-to-noise in the images. FOR SPECTRAL LINE DATA: do not run this step as spectral lines may be weighted down (see also below).

Stage 18. hifv_plotsummary: VLA Plot Summary

This task produces diagnostic plots of the final, calibrated data. This includes phase as a function of time for all sources (calibrators and target), as well as amplitude against uv-distance.

Fig. 32: The Stage 18 hifv_plotsummary task page.

Fig. 32 shows that the calibration around 6:00 and 6:30 is still somewhat noisy and additional flagging of the calibrators may be required. Field 12 looks as expected. One may want to check why some values in field 0 are very low and others in field 11 are quite high. Those could correspond to individual antennas, spws, or polarizations. Again, some editing may be required and the pipeline restarted.

CHECK for: outliers, jumps, offsets, and excessive noise.

Stage 19. hif_makeimlist: Compile a list of cleaned images to be calculated

Finally, diagnostic images are being made for each spw of the phase calibrator. The images and basic parameters such as resolution (cell size) and image sizes are listed in this step. The images are available in the directory in which the pipeline was executed (usually where the SDM is located). At this time, images are being produced for each spw using the multi-frequency synthesis algorithm, ie. in continuum mode that will not have any spectral dependencies and uses the improved uv-coverage due to the frequency range of each spw.

Fig. 33: The Stage 19 hifv_makeimlist task page.

In Fig. 33 the images are listed with 0.31" cell/pixel size and 300 pixels on each side. Names and phase centers are given for each spw.

CHECK for: appropriate cell size for the images.

Stage 20. hif_makeimages: Calculate clean products

The images from the previous stage are shown in the final pipeline task.

Fig. 34: The Stage 20 hifv_makeimages task page.

Imaging parameters are provided for each image (Fig. 34). They contain beam characteristics as well as image statistics. A comparison with the theoretical noise is also provide, which are noise values that are based on bandwidth and integration time for typical VLA array parameters (via the radiometer equation). As mentioned earlier, the quality score is not fully implemented in this version of the pipeline and should be ignored.

CHECK for: degraded images, strong ripples, calibrators that do not resemble the point spread function (psf). Such images may indicate RFI or mis-calibrated sources. If the actual rms is far from the theoretical noise, this could indicate that deeper cleaning is required. But that may not be important for these calibrator images.


Re-Execution of the Pipeline after Flagging

Above we allude to many cases where additional flagging might be required. After manually applying additional flagging (e.g. using flagdata, plotms, viewer/msview or other methods), the pipeline can be re-executed for improved solutions. We do recommend to turn off Hanning smoothing for all re-executions given that the data were already Hanning-smoothed and that flags will be slightly extended by smoothing an already flagged MS.

By default, the pipeline will always revert all flags back to their original state that are saved in the MeasurementSet.flagversions file. It will thus ignore all modification that were made afterwards.

To trick the pipeline, one should manually flag the MeasurementSet and place it in a new directory. Do NOT copy over the related MeasurementSet.flagversions file. Then run the pipeline with the flagged MS for input to hifv.hifv(['MeasuerementSet']). In that case, the pipeline will not be able to recover original flags and will proceed with the manual flags that the user has applied.

Re-Applying Pipeline Results

Pipeline calibration tables can be re-applied to raw data following the description given on the VLA pipeline webage.

Spectral Line Data

The pipeline is not optimized for calibrating spectral line data. Some pipeline steps may be detrimental for spectral line setups and need to be turned off. The calibrators also require enough signal-to-noise to reliably derive bandpass, gains, phases, etc for the likely more narrow spectral line subbands. The pipeline will also flag edge channels for each spw. If the spectral line happens to be located on spw edges, additional modifications to the script may be necessary.

As mentioned above, the following pipeline steps are not advisable for spectral line data:

Stage 2: hifv_hanning: Hanning smoothing dampens the Gibbs ringing from strong spectral features, usually strong, narrow RFI. Hanning smoothing, however, reduces the spectral resolution, which may not be desired for spectral line data. In addition, the typically narrow (and frequently protected) spectral line spws contain less RFI and Hanning smoothing may not be required in the first place. This step is therefore typically turned off for spectral line calibration.

Stage 16. hifv_targetflag: Previous flagging was only applied to the calibrator scans. But Stage 16 attempts to auto-flag all fields including target fields. The rflag mode in flagdata is designed to remove outliers as they deviate from a mean level. (Strong) spectral lines can fulfill this criterion and be flagged. This step should therefore be turned off, too. We recommend manual flagging or a flagdata rflag run that excludes spectral ranges with lines. This step, however, needs to be performed manually after the spectral line pipeline execution.

Stage 17. hifv_statwt: A similar argument applies to the statwt step, where the visibilities are weighted by the inverse of their rms. Spectral lines will increase the rms and will therefore be down-weighted. As this is not desired, the step will be turned off and should be run manually afterwards, tuned to exclude the spectral line frequency range from the weight calculations.


Given the above, we recommend to modify the casa_pipescript.py as in the example below. Surely, the SDM name (here: '13A-398.sb17165245.eb19476558.56374.213876608796' and maybe other parameters will have to be adapted for the run:

__rethrow_casa_exceptions = True
h_init()
 try:
    hifv_importdata(ocorr_mode='co', vis=['13A-398.sb17165245.eb19476558.56374.213876608796'], createmms='automatic', asis='Receiver CalAtmosphere', overwrite=True)
 #   hifv_hanning(pipelinemode="automatic")
    hifv_flagdata(intents='*POINTING*,*FOCUS*,*ATMOSPHERE*,*SIDEBAND_RATIO*, *UNKNOWN*, *SYSTEM_CONFIGURATION*, *UNSPECIFIED#UNSPECIFIED*', flagbackup=False, scan=True, baseband=True, clip=True, autocorr=True, hm_tbuff='1.5int', template=False, online=True, tbuff=0.0, fracspw=0.05, shadow=True, quack=True, edgespw=True)
    hifv_vlasetjy(fluxdensity=-1, scalebychan=True, reffreq='1GHz', spix=0)
    hifv_priorcals(pipelinemode="automatic")
    hifv_testBPdcals(pipelinemode="automatic")
    hifv_flagbaddef(pipelinemode="automatic")
    hifv_checkflag(pipelinemode="automatic")
    hifv_semiFinalBPdcals(pipelinemode="automatic")
    hifv_checkflag(checkflagmode='semi')
    hifv_semiFinalBPdcals(pipelinemode="automatic")
    hifv_solint(pipelinemode="automatic")
    hifv_fluxboot(pipelinemode="automatic")
    hifv_finalcals(pipelinemode="automatic")
    hifv_applycals(pipelinemode="automatic")
 #   hifv_targetflag(pipelinemode="automatic")
 #   hifv_statwt(pipelinemode="automatic")
    hifv_plotsummary(pipelinemode="automatic")
    hif_makeimlist(nchan=-1, calmaxpix=300, intent='PHASE,BANDPASS')
    hif_makeimages(masklimit=4, noise='1.0Jy', subcontms=False, target_list={}, parallel='automatic', maxncleans=1, weighting='briggs', tlimit=2.0, robust=-999.0, npixels=0)
finally:
    h_save()

We commented out the stages 2, 16 and 17. If a spectral line happens to be close to the edge channels, one can decide to turn off edge channel flagging by adding the parameter edgespw=False to all calls of hifv_flagdata.

Once all modifications are made, run the pipeline as:

# In CASA
execfile('casa_pipescript.py')

After the calibration has been obtained, we can now follow up with the flagdata rflag and statwt stages. To start with, we need to define a spw range that contains no lines. Let's assume spw='*:4~180;215~509' is such a range (a line would be in every spw in channels 181 to 214). With this restriction the flagdata task can be run as follows:

# In CASA
flagdata(vis='13A-398.sb17165245.eb19476558.56374.213876608796.ms',
         mode='rflag',spw='*:4~180;215~509',mode='apply')

The spw selection criteria will only flag the line-free part of the spectrum.

statwt will look similar to:

# In CASA
statwt(vis='13A-398.sb17165245.eb19476558.56374.213876608796.ms',
       fitspw='*:4~180;215~509')

where fitspw selects the portion of data that is used for the weight calculation. Again, we use the line-free part of the spectrum.



Mixed Correlator Setups

If data were obtained in mixed correlator modes, the different parts (e.g. spectral line and continuum, or different frequency bands) should be separated first and then the individual parts can be calibrated via the default pipeline or by executing adapted casa_pipescipt.py files. To start with, we recommend to import the SDM to an MS by applying online flags at the same time. For our SDM, the corresponding CASA command would look like:

# In CASA
importasdm(asdm="13A-398.sb17165245.eb19476558.56374.213876608796",
           vis="13A398.sb17165245.eb19476558.56374.213876608796.ms",
           ocorr_mode="co", applyflags=True, savecmds=True, tbuff=1.5,
           outfile="13A-398.sb17165245.eb19476558.56374.213876608796_flagonline.txt")

Note that we apply the online flags via applyflags=True but still save the flag commands in an outfile in case one would like to inspect those. We set tbuff=1.5 to extend the flags to 1.5 times the integration time (which the pipeline would do in hifv_flagdata).

After that step, use the CASA command split to separate the individual parts of the data to be processed individually. Adapt casa_pipescript.py where the newly split out MSs will be used for input.


Polarization Calibration

At this stage, the VLA pipeline does not derive and apply polarization calibration. The user may decide to add polarization calibration steps after the pipeline was run by using the pipeline calibration tables as pre-calibration tables as required.

Polarization calibration steps are explained in the respective section of the 3C391 tutorial (in particular the D-term and crosshand delay calibration will be required). We also refer to the corresponding chapter in the CASA Reference Manual and Cookbook.

Weak Calibrators

The VLA pipeline requires a minimum of signal-to-noise of ~3 for each spw (channel for the bandpass) and target scan. If this criterion is not met, the pipeline will likely fail. We are currently implementing additional heuristics to deal with weak calibration sources. This code will be available in upcoming versions of the VLA pipeline.


Correcting Scan Intents

Scan intents should be set up correctly in the OPT before submitting the schedule block for observation.

When incorrect scan intents are identified after observations, the SDM can be modified and updated with new scan intents. The SDM metadata is structured in the form of an XML and can be manually edited. Great care, however, should be taken not to corrupt the structure of the SDM/xml.

To do so, cd into the SDM and edit the file Scan.xml. We recommend strongly to make a backup copy of the Scan.xml file in case the edits corrupt the metadata.


Scan.xml is divided into individual <row></row> blocks that identify each scan.

E.g. the first scan in our dataset is listed like:

   <row>
       <scanNumber>1</scanNumber>
       <startTime>4870732142800000000</startTime>
       <endTime>4870732322300000256</endTime>
       <numIntent>1</numIntent>
       <numSubscan>1</numSubscan>
       <scanIntent>1 1 OBSERVE_TARGET</scanIntent>
       <calDataType>1 1 NONE</calDataType>
       <calibrationOnLine>1 1 false</calibrationOnLine>
       <sourceName>J1041+0610</sourceName>
       <flagRow>false</flagRow>
       <execBlockId>ExecBlock_0</execBlockId>
   </row>

We can now change the scan intent, e.g. from OBSERVE_TARGET to CALIBRATE_AMPLI by simply updating the <scanIntent> tag:

   <row>
       <scanNumber>1</scanNumber>
       <startTime>4870732142800000000</startTime>
       <endTime>4870732322300000256</endTime>
       <numIntent>1</numIntent>
       <numSubscan>1</numSubscan>
       <scanIntent>1 1 CALIBRATE_AMPLI</scanIntent>
       <calDataType>1 1 NONE</calDataType>
       <calibrationOnLine>1 1 false</calibrationOnLine>
       <sourceName>J1041+0610</sourceName>
       <flagRow>false</flagRow>
       <execBlockId>ExecBlock_0</execBlockId>
   </row>

If we want to add a second intent, we will have to make additional changes. Let's add CALIBRATE_PHASE:

   <row>
       <scanNumber>1</scanNumber>
       <startTime>4870732142800000000</startTime>
       <endTime>4870732322300000256</endTime>
       <numIntent>2</numIntent>
       <numSubscan>1</numSubscan>
       <scanIntent>1 2 CALIBRATE_AMPLI CALIBRATE_PHASE</scanIntent>
       <calDataType>1 2 NONE NONE</calDataType>
       <calibrationOnLine>1 2 false false</calibrationOnLine>
       <sourceName>J1041+0610</sourceName>
       <flagRow>false</flagRow>
       <execBlockId>ExecBlock_0</execBlockId>
   </row>

Inside <scanIntent> we added the second intent, but also increased the second number from 1 to 2. In addition, we specified <numIntent> to be 2, and added a second entry to <calDataType> and <calibrationOnLine>. For the latter two, we also updated the second number from 1 to 2.

Analoguously, if we now add a third intent, CALIBRATE_BANPDASS, to the same scan, the <row> will look like:

   <row>
       <scanNumber>1</scanNumber>
       <startTime>4870732142800000000</startTime>
       <endTime>4870732322300000256</endTime>
       <numIntent>3</numIntent>
       <numSubscan>1</numSubscan>
       <scanIntent>1 3 CALIBRATE_AMPLI CALIBRATE_PHASE CALIBRATE_BANDPASS</scanIntent>
       <calDataType>1 3 NONE NONE NONE</calDataType>
       <calibrationOnLine>1 3 false false false</calibrationOnLine>
       <sourceName>J1041+0610</sourceName>
       <flagRow>false</flagRow>
       <execBlockId>ExecBlock_0</execBlockId>
   </row>


Check with listobs on the imported MS (after executing importasdm or importevla) if the scan intents are now displayed correctly.

Valid intents are (see SDM definition document):

CALIBRATE_AMPLI : Amplitude calibration scan
CALIBRATE_ATMOSPHERE : Atmosphere calibration scan
CALIBRATE_BANDPASS : Bandpass calibration scan
CALIBRATE_DELAY : Delay calibration scan
CALIBRATE_FLUX : flux measurement scan.
CALIBRATE_FOCUS : Focus calibration scan. Z coordinate to be derived
CALIBRATE_FOCUS X : Focus calibration scan; X focus coordinate to be derived
CALIBRATE_FOCUS Y : Focus calibration scan; Y focus coordinate to be derived
CALIBRATE_PHASE : Phase calibration scan
CALIBRATE_POINTING : Pointing calibration scan
CALIBRATE_POLARIZATION : Polarization calibration scan
CALIBRATE_SIDEBAND_RATIO : measure relative gains of sidebands.
CALIBRATE_WVR : Data from the water vapor radiometers (and correlation data) are used to derive their calibration parameters.
DO_SKYDIP : Skydip calibration scan
MAP_ANTENNA_SURFACE : Holography calibration scan
MAP_PRIMARY_BEAM : Data on a celestial calibration source are used to derive a map of the primary beam.
OBSERVE_TARGET : Target source scan
CALIBRATE_POL_LEAKAGE :
CALIBRATE_POL_ANGLE :
TEST : used for development.
UNSPECIFIED : Unspecified scan intent
CALIBRATE_ANTENNA_POSITION : Requested by EVLA.
CALIBRATE_ANTENNA_PHASE : Requested by EVLA.
MEASURE_RFI : Requested by EVLA.
CALIBRATE_ANTENNA_POINTING_MODEL : Requested by EVLA.
SYSTEM_CONFIGURATION : Requested by EVLA.
CALIBRATE_APPPHASE_ACTIVE : Calculate and apply phasing solutions. Applicable at ALMA.
CALIBRATE APPPHASE PASSIVE : Apply previously obtained phasing solutions. Applicable at ALMA.
OBSERVE_CHECK_SOURCE

Revert back to the original Scan.xml if the above was not successful and contact the NRAO helpdesk for advice.

Scripted Pipeline

In addition to the pipeline that is delivered with CASA, one can also use the VLA scripted pipeline. More modifications are possible to the scripted pipeline and it can be altered to work in almost any circumstance. We refer to the VLA scripted Pipeline webpage for details.


Last checked on CASA Version 4.5.3