MRK 6: red-shifted HI absorption 5.5.0

From CASA Guides
Jump to navigationJump to search

VLA Tutorials


Overview

This example demonstrates a trickier spectral line data set. In this case, several radio bright active galaxies were observed to look for redshifted 21 cm absorption. The data were obtained using 4IF mode, which means that the full range of velocities were split into two spectral windows (in this example, CASA identifies them as spectral windows 14 and 15). Producing the data cube will require eventually stitching these windows back together.

Download your data from the VLA Archive; in this example we'll use the publicly available survey AB658. These data were published in Gallimore et al. (1999).

With the present archive defaults, you should have obtained the following VLA archive files.

'AB658_A921122.xp1'
'AB658_A921122.xp2'
'AB658_A921122.xp3'
'AB658_A921122.xp4'

This tutorial broadly follows the techniques described in the continuum survey tutorial and the 21 cm emission tutorial, and the basic calibration steps are presented only in outline.

Loading the Data

Recall that the python file globber glob is your friend here!

measurementSet = "ab658.ms" # Store the desired name of the measurement set

from glob import glob
fileList = sorted(glob("AB658*.xp?"))

# double check to see if the file already exists
import os

if not os.path.isdir("./" + measurementSet): # measurement sets are directories
    importvla(archivefiles=fileList, vis=measurementSet) # only import if ab658.ms doesn't yet exist

vis = measurementSet
mode = "summary"
vishead

For the purposes of this tutorial, we are interested only in the source Markarian 6, but the reduction techniques could be applied to any of the sources in the measurement set.

Using listobs and plotxy we learn the source names, spectral windows, and viable reference antennas.

Source MKN6
Amp Cal 0134+329 = 3C48
Phase Cal 1003+830
Central Antennas VA27, VA09, VA23
Spectral Window IDs 14, 15

It's just as well to put that information into python global variables.

sourceName = "MKN6"
phaseCal = "1003+830"
ampCal = "0134+328"
refAnt = "VA27" # or perhaps "VA09" or "VA23"
spw0 = 14
spw1 = 15

Editing the Data

Plotms display of (uncalibrated) visibility amplitudes vs. time for the source MKN6.

First inspect the data using plotms.

default(plotms)
vis = measurementSet
field = ampCal
plotms

Be sure to select Axes → X Axis → Time and Axes → Y Axis → Amp (those settings are likely the default). There is some obvious junk isolated in time; see the screenshot at right. Follow the tutorial to flag discrepant data for this, the amplitude calibrator, as well as the source and phase calibrator.

Calibration

Calibration of HI absorption spectra follows the basic techniques outlined in the continuum tutorial and HI emission tutorial.