Imaging a Mosaicked Spectral Line Dataset: Difference between revisions

From CASA Guides
Jump to navigationJump to search
(Created page with 'This page assumes you have completed Calibrating a Mosaicked Spectral Line Dataset; please return there if you need to consult these steps again. As before, these notes assu…')
 
No edit summary
Line 1: Line 1:
[[CARMA Tutorials | &#8629; '''CARMA Tutorials''']] <br>
[[Main Page | &#8629; '''CASAguides''']]
This page assumes you have completed [[Calibrating a Mosaicked Spectral Line Dataset]]; please return there if you need to consult these steps again.
This page assumes you have completed [[Calibrating a Mosaicked Spectral Line Dataset]]; please return there if you need to consult these steps again.


Line 24: Line 27:
       weighting='natural')
       weighting='natural')
</source>
</source>
[[CARMA Tutorials | &#8629; '''CARMA Tutorials''']] <br>
[[Main Page | &#8629; '''CASAguides''']]

Revision as of 16:36, 28 December 2009

CARMA Tutorials
CASAguides

This page assumes you have completed Calibrating a Mosaicked Spectral Line Dataset; please return there if you need to consult these steps again.

As before, these notes assume that you have made the following global definitions in CASA:

# In CASA
msdir='./'
project='c0xxx'
msfile=msdir+project+'.ms'


# In CASA
clean(vis=msfile,imagename='clean3pb_07dec',spw='1,2',field='3~51',
      phasecenter='J2000 20h35m35.32 60d10m01.00',
      cell=2.,imsize=[400,400],
      mode='velocity',start='-103.00km/s',width='5.08km/s',nchan=29,
      interpolation='linear',psfmode='clark',
      imagermode='mosaic',ftmachine='mosaic',
      scaletype='SAULT',restfreq='115.2712GHz',interactive=F,
      minpb=0.1,pbcor=True,
      niter=1000,threshold='340mJy',mosweight=False,
      weighting='natural')

CARMA Tutorials
CASAguides