IRAS16293 Band9 - Imaging for CASA 3.4

From CASA Guides
Revision as of 12:52, 23 May 2012 by Trejo (talk | contribs)
Jump to navigationJump to search

Overview

This section of the casa guide continues from the last step of the calibration one. If you completed the calibration section, then you already have the final calibrated dataset. If you just started to work on this IRAS16293 B9 data, you can download the fully calibrated dataset IRAS16293_Band9_CalibratedMS from

North America

Europe

East Asia

This casa guide covers imaging of both continuum and line of IRAS16293 Band 9. The commands in this guide should be executed in CASA 3.4.0 since CASA 3.3.0 would be very slow for the cleaning process of a big dataset like this one for IRAS16293 Band 9. In this casa guide you will also need the Analysis Utils package, so make sure you have it imported into CASA.

Before we start with the imaging itself, do a listobs to the calibrated dataset, so you can check that everything is ok.

# listobs to check data
listobs(vis='IRAS16293_Band9.ms',
        listfile='IRAS16293_Band9.ms.listobs',verbose=F)

You should see the next information in the .listobs file.

Fields: 7
  ID   Code Name                RA              Decl          Epoch   SrcId 
  0    none IRAS16293-2422-a    16:32:22.99200 -24.28.36.0000 J2000   0     
  1    none IRAS16293-2422-a    16:32:22.47925 -24.28.36.0000 J2000   0     
  2    none IRAS16293-2422-a    16:32:22.73563 -24.28.36.0000 J2000   0     
  3    none IRAS16293-2422-a    16:32:22.73563 -24.28.32.5000 J2000   0     
  4    none IRAS16293-2422-a    16:32:22.47925 -24.28.29.0000 J2000   0     
  5    none IRAS16293-2422-a    16:32:22.73563 -24.28.29.0000 J2000   0     
  6    none IRAS16293-2422-a    16:32:22.99200 -24.28.29.0000 J2000   0     
   (nVis = Total number of time/baseline visibilities per field) 
Spectral Windows:  (4 unique spectral windows and 1 unique polarization setups)
  SpwID  #Chans Frame Ch1(MHz)    ChanWid(kHz)  TotBW(kHz)  Corrs  
  0        3840 TOPO  703312.744  488.28125     1875000     XX  YY  
  1        3840 TOPO  692237.256  488.28125     1875000     XX  YY  
  2        3840 TOPO  690437.256  488.28125     1875000     XX  YY  
  3        3840 TOPO  688437.256  488.28125     1875000     XX  YY  
Antennas: 14 'name'='station' 
   ID=   0-3: 'DA41'='A003', 'DA43'='A075', 'DA47'='A026', 'DV02'='A077', 
   ID=   4-7: 'DV03'='A137', 'DV05'='A082', 'DV07'='A076', 'DV09'='A046', 
   ID=  8-11: 'DV10'='A071', 'DV12'='A011', 'DV13'='A072', 'DV14'='A025', 
   ID= 12-13: 'DV17'='A138'

Continuum Emission Imaging

As it is shown in Figures 2 and 3 of IRAS16293Band9, these observations have a 7 pointing mosaic, which you can visualize with the next command (see also Figure 1).

Fig. 1. Pointings showing the mosaic used for the observations.
# Make a plot of the mosaic pattern with field ids identified
aU.plotMosaic(vis='IRAS16293_Band9.ms',sourceid='0',
              doplot=True,figfile='mosaic_pattern.png')

You might wander what of these pointings or fields have stronger line emission. You can know this by running the next command. We set spw='1' containing CO (6-5), and you can check all the plots for all the fields by just hitting the arrow for "next". Also see Figure 2 for an example of the output.

Fig. 2. UV-amp distribution for the field 2 in the mosaic.
# See which mosaic fields have the brightest line emission
plotms(vis='IRAS16293_Band9.ms', 
       field='',xaxis='uvdist', yaxis='amp',
       spw='1', avgchannel='3840',coloraxis='field',
       iteraxis='field')

Another way to visualize the uv-amp distribution is with the next plotms. This will load all the fields or pointing into the plot, and you can change interactively between the spws using the appropriate button in plotms. See Figure 3 for a plot of spw 1.

Fig. 3. UV-amp distribution for spw 1 using all the fields or pointings in the mosaic.
# Iterate over spws all fields
plotms(vis='IRAS16293_Band9.ms', 
       field='',xaxis='uvdist', yaxis='amp',
       spw='', avgchannel='3840',coloraxis='field',
       iteraxis='spw')

We need to note the channels that do not present line emission. To identify them we can plot the amplitude vs frequency for all the spectral windows. Figure 4 shows the output from the next command for spw 1.

Fig. 4. Frequency-amplitude plot for spw 1 using the fields 0 and 4.
# Select Channels for uvcontsub. Average every 8 channels for
# increased S/N.

plotms(vis='IRAS16293_Band9.ms', 
       xaxis='channel', yaxis='amp',field='0,4',
       spw='', avgtime='1e8',avgscan=T,coloraxis='field',
       avgchannel='8',iteraxis='spw',ydatacolumn='corrected',
       xselfscale=True,yselfscale=True)

Using the plots from the previous command you can select the line emission free channels just by looking for strong lines. To do this in the rigorous way, you would need to make dirty images and then select the continuum channels. Here we provide you with the channel selection we used for emission.

Now uvcontsub will be used to calculate the level of continuum (based on your selection of continuum channels) and subtract that from the dataset.

# subtracting the continuum
contspw='0:20~1700;2500~3820,1:20~400;500~1100;1900~3000;3450~3800,2:20~1700;2200~3100,3:800~1600;2900~3300'
uvcontsub(vis='IRAS16293_Band9.ms',fitspw=contspw,fitorder=1,combine='spw')

Last checked on CASA Version 3.4.0.