The primer (or "cheat sheet") is intended to help those VLBA users who are used to calibrating and imaging their data in AIPS transition to CASA.

It presents the AIPS VLBAUTIL procedures, the AIPS task(s) associated with those procedures, and the equivalent CASA task(s) and/or tool(s).

Loading Data

Both AIPS and CASA need to take the FITS-IDI file and convert it into a format they can use. AIPS uses the UVDATA format, and CASA uses the Measurement Set (MS) format.

VLBAUTIL Procedure AIPS Task(s) CASA Task(s)
VLBALOAD FITLD importfitsidi


Observation Summary

Printing a summary of the observation is often useful for identifying the fringe finder, bandpass calibrator, phase reference calibrator, and science target. It is also useful for locating a good time range to use for the instrumental delay correction.

VLBAUTIL Procedure AIPS Task(s) CASA Task(s)
VLBASUMM PRTAN listobs
LISTR
optype 'scan'


Total Electron Content Correction

VLBAUTIL Procedure AIPS Task(s) CASA Task(s)
VLBATECR TECOR no equivalent CASA task yet

NOTE: Do not use the tec_maps tool with VLBA data. It does not work properly for VLBI observations.


Earth Orientation Parameter Correction

VLBAUTIL Procedure AIPS Task(s) CASA Task(s)
VLBAEOPS CLCOR
opcode 'eops'
no equivalent CASA task yet


Sampler Corrections

VLBAUTIL Procedure AIPS Task(s) CASA Task(s)
VLBACCOR ACCOR accor
SNSMO smoothcal