Polcal
From CASA Guides
Help on polcal task:
Determine instrumental polarization calibrations The instrumental polarization factors (D-terms), the calibrator polarization, and the R-L polarization angle can be determined using polcal. The solutions can be obtained for each antenna/spwid and even individual channels, if desired. Previous calibrations of the total intensity data should be applied on the fly when running polcal, since polcal uses the 'data' column, not the 'corrected' column. After calibrating the total intensities, the simplest way to calibrate the polarization data is: a) Run polcal with poltype = 'D+QU' on the main 'calibrator' source. The D terms and polarization (QU) of the calibrator will be determined. Relatively good parallactic angle coverage is needed. b) If there is little parallactic angle coverage, place the known calibration of the main calibrator (or 0) using setjy with the appropriate fluxdensity. Then run polcal with poltype = 'D'. Run plotcal with xaxis = 'real'; yaxis ='imag' to view solutions. c) To determine R-L polarization angle, use setjy to put the fluxdensity of the polarization calibrator [I,Q,U,0.0] in the model column. For resolved sources put in values associated with an appropriate u-v range. Polarized models are not yet available for the major polarization standard sources, so very resolved polarized sources should not be used. d) Run polcal with poltype = 'X' and include polarization standard. Make sure to include all previous calibrations, especially the D results. Run plotxy with correlation = 'RL LR' and make sure polarization angles are as expected. e) Run applycal with all calibration table, include the D and X tables. Make sure that parang = T NOTE: For very high dynamic range, add 'f' after D to determine D terms for each channel. Keyword arguments: vis -- Name of input visibility file default: none; example: vis='ngc5921.ms' caltable -- Name of output gain calibration table default: none; example: caltable='ngc5921.dcal' --- Data Selection (see help par.selectdata for more detailed information) field -- Select field using field id(s) or field name(s). [run listobs to obtain the list id's or names] default: ''=all fields. Most likely, the main calibrator source should be picked. If field string is a non-negative integer, it is assumed a field index otherwise, it is assumed a field name field='0~2'; field ids 0,1,2 field='0,4,5~7'; field ids 0,4,5,6,7 field='3C286,3C295'; field named 3C286 adn 3C295 field = '3,4C*'; field id 3, all names starting with 4C spw -- Select spectral window/channels type 'help par.selection' for more examples. spw='0~2,4'; spectral windows 0,1,2,4 (all channels) spw='<2'; spectral windows less than 2 (i.e. 0,1) spw='0:5~61'; spw 0, channels 5 to 61, INCLUSIVE spw='*:5~61'; all spw with channels 5 to 62 spw='0,10,3:3~45'; spw 0,10 all channels, spw 3, channels 3 to 45. spw='0~2:2~6'; spw 0,1,2 with channels 2 through 6 in each. spw='0:0~10;15~60'; spectral window 0 with channels 0-10,15-60 NOTE ';' to separate channel selections spw='0:0~10^2,1:20~30^5'; spw 0, channels 0,2,4,6,8,10, spw 1, channels 20,25,30 selectdata -- Other data selection parameters default: True timerange -- Select data based on time range: default = '' (all); examples, timerange = 'YYYY/MM/DD/hh:mm:ss~YYYY/MM/DD/hh:mm:ss' Note: if YYYY/MM/DD is missing dat defaults to first day in data set timerange='09:14:0~09:54:0' picks 40 min on first day timerange= '25:00:00~27:30:00' picks 1 hr to 3 hr 30min on next day timerange='09:44:00' data within one integration of time timerange='>10:24:00' data after this time uvrange -- Select data within uvrange (default units meters) default: '' (all); example: uvrange='0~1000'; uvrange from 0-1000 kilo-lamgda uvrange='>4';uvranges greater than 4 kilo-lambda antenna -- Select data based on antenna/baseline default: '' (all) If antenna string is a non-negative integer, it is assumed an antenna index otherwise, it is assumed as an antenna name antenna='5&6'; baseline between antenna index 5 and index 6. antenna='VA05&VA06'; baseline between VLA antenna 5 and 6. antenna='5&6;7&8'; baseline 5-6 and 7-8 antenna='5'; all baselines with antenna index 5 antenna='05'; all baselines with antenna name 05, i.e. VLA ant 5 antenna='5,6,10'; all baselines with antennas 5, 6 and 10 scan -- Scan number range msselect -- Optional complex data selection (ignore for now) --- Solution parameters poltype -- Type of instrumental polarization solution 'D+QU' (or 'Df+QU') solve also for apparent source polarization (channelized D) Need relatively good parallactic angle coverage for this 'D' (or 'Df') solve only for instrumental polarization (channelized). The I, Q, U flux density of the source can be placed in the model column using setjy. Use for poor parallactic angle coverage. 'X' = solve only for position angle correction. The source must have its I, Q, U flux density in the model column. If the source is resolved, use a uvrange that is appropriate. 'D+X' (or 'Df+X') = solve also for position angle offset (channelized D) as well as the D-term. Not normally done. default: 'D+QU' The solution used the traditional linear approximation. Non-linearized options will be avaible soon. solint -- Solution interval (units optional) default: 'inf' (~infinite, up to boundaries controlled by combine); Options: 'inf' (~infinite), 'int' (per integration), any float or integer value with or without units examples: solint='1m'; solint='60s', solint=60 --> 1 minute solint='0s'; solint=0; solint='int' --> per integration solint-'-1s'; solint='inf' --> ~infinite, up to boundaries enforced by combine combine -- Data axes to combine for solving default: 'scan' --> solutions will break at field and spw boundaries, but may extend over multiple scans (per field and spw) up to solint. Options: '','scan','spw',field', or any comma-separated combination example: combine='scan,spw' --> extend solutions over scan boundaries (up to the solint), and combine spws for solving preavg -- Pre-averaging interval (sec) default=300 Interval to apply parallactic angle. refant -- Reference antenna name default: '' => refant = '0' example: refant='13' (antenna with index 13) refant='VA04' (VLA antenna #4) Use 'go listobs' for antenna listing. USE SAME REFERENCE ANTENNA AS USED FOR I CALIBRATION. minblperant -- Minimum number of baselines required per antenna for each solve Antennas with fewer baaselines are excluded from solutions. Amplitude solutions with fewer than 4 baselines, and phase solutions with fewer than 3 baselines are only trivially constrained, and are no better than baseline-based solutions. default: 4 example: minblperant=10 => Antennas participating on 10 or more baselines are included in the solve minsnr -- Reject solutions below this SNR default: 0.0 (accept all attempted solutions) append -- Append solutions to the (existing) table default: False; overwrite existing table or make new table --- Other calibrations to apply on the fly before determining gaincal solution gaintable -- Gain calibration table(s) to apply default: '' (none); BUT I CALIBRATION TABLES SHOULD GENERALLY BE INCLUDED examples: gaintable='ngc5921.gcal' gaintable=['ngc5921.ampcal','ngc5921.phcal'] gainfield -- Select a subset of calibrators from gaintable(s) default:'' ==> all sources in table; same syntax as field example: gainfield='0~3' gainfield=['0~3','4~6'] means use field 0 through 3 from first gain file, field 4 through 6 for second. interp -- Interpolation mode (in time) to use for each gaintable default: '' --> 'linear' for all gaintable(s) example: interp='nearest' interp=['nearest','linear'] Options: 'nearest', 'linear', 'aipslin' spwmap -- Spectral windows combinations to form for gaintable(s) default: [] (apply solutions from each spw to that spw only) Example: spwmap=[0,0,1,1] means apply the caltable solutions from spw = 0 to the spw 0,1 and spw 1 to spw 2,3. spwmap=[[0,0,1,1],[0,1,0,1]] gaincurve -- Apply internal VLA antenna gain curve correction (True/False) default: False; Use gaincurve=True ONLY for VLA data opacity -- Opacity correction to apply (nepers) default: 0.0 (no opacity correction) example: opacity=0.051 Typical VLA values are: 5 GHz - 0.013, 8 GHz - 0.013 15 GHz - 0.016, 23 GHz - 0.051, 43 GHz - 0.07 async -- Run asynchronously default = False; do not run asychronously