CASA Contributed Script: vlacal-setjy: Difference between revisions
No edit summary |
|||
Line 161: | Line 161: | ||
<div style="background-color: #CCFF99;"> | <div style="background-color: #CCFF99;"> | ||
Last checked on CASA Version 6. | Last checked on CASA Version 6.4.0. | ||
</div> | </div> |
Revision as of 03:03, 1 November 2021
This page is currently under development.
Please do not use this guide until this message has been removed.
Introduction
Flux-density calibration for the VLA typically involves an observation of one of four primary calibrators: 3C286, 3C48, 3C138 and 3C147. Models for these sources are distributed as part of the CASA package and model visibilities are predicted using the task setjy. The most current models available in setjy are accessible using the flux-density standard Perley Butler 2017 (hereafter PB17), which is based on observations conducted on or before January 2016. See this link for further discussion of VLA flux-density calibration.
Given the recent and significant variability in some primary calibrators (i.e., 3C48 and 3C147) NRAO staff are in the process of creating a new flux-density standard based on more recent observations. Instead of packaging these new models with CASA, NRAO will host a database that is continually updated with the latest monitoring data (having an approximately monthly cadence). A new flux-density standard will be added to the task setjy to make use of these new models (estimated release date 2023). Until the new version of setjy is released, this contributed script vlacal-setjy.py can be executed to obtain the newest models from the database. This casaguide provides documentation and examples of how to use this script. Please ensure you are using a recent version of CASA to run the script (this guide was tested using CASA v6.4.0, and the script is known not to work in CASA versions <= 5.8).
Obtaining the script
The script vlacal-setjy.py is available for download here. Please save a copy in your local working directory, e.g.,
# in CASA
!wget www.aoc.nrao.edu/~jmarvil/vlacal-setjy.py
Loading the functions
Next, you will want to run the script in CASA, i.e.,
# in CASA
execfile('vlacal-setjy.py')
This will import functions that you can now run from your CASA session. You will need to run the script each time you start CASA if you want these functions to be available (or add the above to startup.py). Note that there is no need to open the script in an editor or make any modifications to it.
Calculating a flux-density ratio
One function provided by this script will calculate the ratio of the PB17 flux to the new NRAO flux standard. This ratio may be of interest to users who have already calibrated their data using the PB17 flux standard. In this case, the ratio could be used to scale the visibility amplitude or the image intensity. The function to calculate this ratio is called vlacal_setjy_calculate_ratio. The following functional arguments will need to be provided:
- source: The string name of the VLA primary calibrator, i.e., one of '3C286', '3C48', '3C138' or '3C147'
- band: The single-letter string name of the VLA receiver band, i.e., one of 'P', 'L', 'S', 'C', 'X', 'U', 'K', 'A' or 'Q'
- date: The date to determine the flux-density scale (typically the date your observation took place), formatted as'YYYY/MM/DD'
For example, for source 3C48 at Ka-band on June 1, 2019 you would run:
# in CASA
vlacal_setjy_calculate_ratio( source='3C48', band='A', date='2019/06/01' )
which will produce the following output:
Obtained flux of 1.074 Jy on mjd 58635.0 for source 3C48 at reference frequency 33.25 GHz This interpolated flux differs from Perley-Butler 2017 by 32.65%
Based on this output, one could scale their results by a factor of 1.3265 to account for the estimated flux of 3C48 at their time of observation.
Recalibrating your visibilities
The setjy replacement function
Another function provided by this script will fill the MODEL_DATA column of your measurement set. This is intended to replace the running of the task setjy in the VLA calibration procedure. The setjy replacement function is called vlacal_setjy_predict_model_data. The following functional arguments will need to be provided:
- vis: The string name of the measurement set to be processed
- field: The string field ID(s) of the primary calibrator to be processed, e.g., '0'. All selected fields need to be for the same source.
- source: The string name of the VLA primary calibrator corresponding to the field parameter, i.e., one of '3C286', '3C48', '3C138' or '3C147'
- spw: The CASA spectral window selection string to be processed. All SPWs need to be from the same receiver band.
- band: The single-letter string name of the VLA receiver band corresponding to the spw parameter, i.e., one of 'P', 'L', 'S', 'C', 'X', 'U', 'K', 'A' or 'Q'
- date: The date to determine the flux-density scale (typically the date your observation took place), formatted as'YYYY/MM/DD'
If your measurement set contains multiple primary flux calibrators and/or multiple receiver bands then you will need to run the above function once per source/band combination, identifying the appropriate field-source and spw-band relationships for each combination.
Example function usage
In this example, we will use the following measurement set: vlacal_example.ms.tar.gz (82 MB)
We will download and untar the example measurement set, then run the task listobs to view a summary of its contents.
# in CASA
listobs( vis='vlacal_example.ms', verbose=True )
A portion of the listobs output is shown below, as it appears in the log file and the logger window:
================================================================================ MeasurementSet Name: vlacal_example.ms MS Version 2 ================================================================================ Observer: Lorant Sjouwerman Project: uid://evla/pdb/36543887 Observation: EVLA Computing scan and subscan properties... Data records: 84721 Total elapsed time = 518 seconds Observed from 30-Nov-2019/08:53:26.0 to 30-Nov-2019/09:02:04.0 (UTC) ObservationID = 0 ArrayID = 0 Date Timerange (UTC) Scan FldId FieldName nRows SpwIds Average Interval(s) ScanIntent 30-Nov-2019/08:53:26.0 - 08:53:50.0 27 0 0137+331=3C48 18977 [0,1,2,3,4,5,6,7] [2, 2, 2, 2, 2, 2, 2, 2] [CALIBRATE_AMPLI#UNSPECIFIED,CALIBRATE_PHASE#UNSPECIFIED] 08:53:54.0 - 08:54:20.0 28 0 0137+331=3C48 19160 [8,9,10,11,12,13,14,15] [2, 2, 2, 2, 2, 2, 2, 2] [CALIBRATE_AMPLI#UNSPECIFIED,CALIBRATE_PHASE#UNSPECIFIED] 09:01:08.0 - 09:01:34.0 38 1 J0319+4130 23096 [0,1,2,3,4,5,6,7] [2, 2, 2, 2, 2, 2, 2, 2] [CALIBRATE_AMPLI#UNSPECIFIED,CALIBRATE_PHASE#UNSPECIFIED] 09:01:38.0 - 09:02:04.0 39 1 J0319+4130 23488 [8,9,10,11,12,13,14,15] [2, 2, 2, 2, 2, 2, 2, 2] [CALIBRATE_AMPLI#UNSPECIFIED,CALIBRATE_PHASE#UNSPECIFIED] (nRows = Total number of rows per scan) Fields: 2 ID Code Name RA Decl Epoch SrcId nRows 0 NONE 0137+331=3C48 01:37:41.299431 +33.09.35.13299 J2000 0 38137 1 NONE J0319+4130 03:19:48.160102 +41.30.42.10305 J2000 1 46584 Spectral Windows: (16 unique spectral windows and 1 unique polarization setups) SpwID Name #Chans Frame Ch0(MHz) ChanWid(kHz) TotBW(kHz) CtrFreq(MHz) BBC Num Corrs 0 EVLA_Q#A0C0#68 64 TOPO 39988.000 2000.000 128000.0 40051.0000 12 RR LL 1 EVLA_Q#A0C0#69 64 TOPO 40116.000 2000.000 128000.0 40179.0000 12 RR LL 2 EVLA_Q#A0C0#70 64 TOPO 40244.000 2000.000 128000.0 40307.0000 12 RR LL 3 EVLA_Q#A0C0#71 64 TOPO 40372.000 2000.000 128000.0 40435.0000 12 RR LL 4 EVLA_Q#A0C0#72 64 TOPO 40500.000 2000.000 128000.0 40563.0000 12 RR LL 5 EVLA_Q#A0C0#73 64 TOPO 40628.000 2000.000 128000.0 40691.0000 12 RR LL 6 EVLA_Q#A0C0#74 64 TOPO 40756.000 2000.000 128000.0 40819.0000 12 RR LL 7 EVLA_Q#A0C0#75 64 TOPO 40884.000 2000.000 128000.0 40947.0000 12 RR LL 8 EVLA_K#A0C0#84 64 TOPO 20188.000 2000.000 128000.0 20251.0000 12 RR LL 9 EVLA_K#A0C0#85 64 TOPO 20316.000 2000.000 128000.0 20379.0000 12 RR LL 10 EVLA_K#A0C0#86 64 TOPO 20444.000 2000.000 128000.0 20507.0000 12 RR LL 11 EVLA_K#A0C0#87 64 TOPO 20572.000 2000.000 128000.0 20635.0000 12 RR LL 12 EVLA_K#A0C0#88 64 TOPO 20700.000 2000.000 128000.0 20763.0000 12 RR LL 13 EVLA_K#A0C0#89 64 TOPO 20828.000 2000.000 128000.0 20891.0000 12 RR LL 14 EVLA_K#A0C0#90 64 TOPO 20956.000 2000.000 128000.0 21019.0000 12 RR LL 15 EVLA_K#A0C0#91 64 TOPO 21084.000 2000.000 128000.0 21147.0000 12 RR LL
From the listobs output we can see that field ID 0 is the VLA primary flux calibrator 3C48, so we will set field='0' and source='3C48'. We also see that 3C48 was observed in two different receiver bands, i.e., K and Q. This means we will need to run the function 'vlacal_setjy_predict_model_data' twice, first with band='Q' and spw='0~7', then with band='K' and spw='8~15'. Finally, we can read the observation date from the listobs output and format it as required by the function, i.e., date='2019/11/30'.
We are now ready to run the function to predict the model visibilities for field ID 0:
# in CASA
vlacal_setjy_predict_model_data( vis='vlacal_example.ms', field='0', source='3C48', spw='0~7', band='Q', date='2019/11/30' )
vlacal_setjy_predict_model_data( vis='vlacal_example.ms', field='0', source='3C48', spw='8~15', band='K', date='2019/11/30' )
which will produce the following output:
Interpolated 3C48 flux on mjd 58817 of 0.854 Jy at reference frequency 45.0 GHz Filling MODEL_DATA column using task_ft for data selection: field='0', spw='0~7' Interpolated 3C48 flux on mjd 58817 of 1.469 Jy at reference frequency 22.25 GHz Filling MODEL_DATA column using task_ft for data selection: field='0', spw='8~15'
The MODEL_DATA column has now been filled using the most current monitoring data from the new NRAO VLA flux-density standard. The standard calibration procedure may now continue, having run this function instead of setjy. We recommend the following line be included in publications using these data:
"These data were calibrated using 3C48, assuming a flux density of 0.854 Jy at 45 GHz and 1.469 Jy at 22.25 GHz, as obtained using the NRAO VLA flux-density standard."
Questions about this tutorial? Please contact the NRAO Helpdesk.
Last checked on CASA Version 6.4.0.