Data flagging with viewer: Difference between revisions
No edit summary |
No edit summary |
||
Line 181: | Line 181: | ||
</div> | </div> | ||
To flag additional data, zoom out [[File: zoomOut.png]], select correlations [[File:vcrNext.png]] as necessary, and repeat the steps outlined above. | To flag additional data, zoom out [[File: zoomOut.png]], select correlations [[File:vcrNext.png]] as necessary, and repeat the steps outlined above. | ||
It is absolutely vital to save your edits before leaving [[viewer]]. From the '''Data Display Options''' window, select '''Flagging Options''' and '''Save Edits''' (see figure at right). You are now ready for calibration and imaging! | It is absolutely vital to save your edits before leaving [[viewer]]. From the '''Data Display Options''' window, select '''Flagging Options''' and '''Save Edits''' (see figure at right). You are now ready for calibration and imaging! | ||
Revision as of 19:57, 14 February 2010
Overview
Your data will inevitably have some bad data. Perhaps a receiver on a given antenna is acting up, or perhaps the pointing on a given antenna is poor, and these problematic data will (hopefully) appear obviously in your measurement set. It's a good idea to inspect your data carefully before calibration and imaging, and CASA offers several tools to flag bad data interactively. For loyal users of TVFLG and SPFLG in AIPS, you'll be happy to know that viewer reproduces and even enhances these functionalities.
This tutorial illustrates how to use viewer to flag poor quality data. It will use the continuum dataset AU079 from the VLA archive; this dataset is also used in the Imaging Flanking Fields and Data flagging with casaplotms tutorials.
Loading the Measurement Set into Viewer
As described in the Imaging Flanking Fields tutorial, the data may be loaded into CASA using the importvla command. The following commands import the data into the measurement set au079.ms and send them to the viewer.
# from loaddata.py
from glob import glob
# Define the list of files for reading. Use glob to perform wildcard matching with VLA archive filenames.
fileList = glob('AU079_*.xp?')
importvla(archivefiles=fileList,vis='au079.ms')
viewer('au079.ms') # load the data into the viewer for editing
The viewer command can also be invoked without argument, in which case a file selector GUI will appear.
Setting Up for Antenna-based Flagging
The figure at right shows the default viewer display for a measurement set. The axes are (y) time and (x) baseline, or antenna pair, enumerated by the common antenna number of the pair (like TVFLG in AIPS). Flagged data are highlighted in pale blue. Another window, titled Data Display Options, will also appear, allowing you to alter the display and flagging options. |
The blue highlights can be initially distracting, and they can be optionally suppressed by altering the Flagging Options in the Data Display Options. The figure at right shows the options.
In anticipation of the antenna-based editing to come, it's also worth setting the antenna flag.
Now, when multiple baselines are selected, all baselines to the common antenna will be flagged. There are also options to flag all correlations or channels, the latter being particularly helpful for spectral-line experiments. |
There is a choice of data to display. Select the MS and Visibility Selection tab on the Data Display Options window; see the figure at right. The Visibility Component menu allows you to choose to display visibility data from the following list.
The rolling time windows needed to calculate the Diff and RMS options are tuned using the Moving Average Size slider. All of these options are useful to investigate aberrant data, but Amp Diff can be efficient to start with. Reasonable options are shown in the figure at right. Be sure to turn down the display maximum (Data Maximum under Basic Settings) to bring out the fainter variations. You can also select a single source, or subset of sources, to display using the Field IDs blank. After you change the Field IDs box, you'll probably need to click on the Apply button. If you don't see the button, scroll all the way down in the Data Display Options window (Note that you don't see the Apply button in the figure to the immediate right because several submenus are open, but you can see it in the figure above). |
The result of these operations is illustrated in the figure at right. Data from the RR correlation are shown, but you can easily select the other correlations (RL, LR, LL) by using the blue, DVD-style control buttons below the main display. Tip: For spectral line datasets, you'll probably also want to use the DVD-style control buttons to step through spectral channels. You can change which data dimension is affected by these control buttons with the Animation Axis menu, located under Display Axes in the Data Display Options window.
|
Tip: For spectral line datasets, you might also like to display (y) time against (x) spectral channel (as in AIPS SPFLG). You can do this by going to Display Axes in the Data Display Options and selecting X Axis as Channel.
Antenna-Based Flagging
The following steps outline flagging with viewer.
- Zoom in on junky-looking data using the zoom tool .
- Use one of the drawing selectors to identify the bad data.
- Zoom out and repeat.
- Important: save your edits! Under Flagging Options, use the Save Edits button.
This section of the tutorial provides a more detailed walkthrough.
Finishing up
To flag additional data, zoom out , select correlations as necessary, and repeat the steps outlined above.
It is absolutely vital to save your edits before leaving viewer. From the Data Display Options window, select Flagging Options and Save Edits (see figure at right). You are now ready for calibration and imaging!
Displaying Calibrated Data
You might like to double-check the data after calibration, to ensure that the calibration looks good and no new bad data has popped up. You can do this easily by selecting 'corrected' as the Visibility Type, which can be found in MS and Visibility Selection section of the Data Display Options.
--Jack Gallimore 19:14, 23 November 2009 (UTC)