Imaging your Mosaicked Spectral Line Dataset: Difference between revisions
From CASA Guides
Jump to navigationJump to search
Created page with 'This page assumes you have completed Calibrating a Mosaicked Spectral Line Dataset; please return there if you need to consult these steps again. As before, these notes assu…' |
m moved Imaging your Mosaicked Spectral Line Dataset to imaging your Mosaicked Spectral Line Dataset: Converting page titles to lowercase |
(No difference)
|
Revision as of 20:43, 16 March 2012
This page assumes you have completed Calibrating a Mosaicked Spectral Line Dataset; please return there if you need to consult these steps again.
As before, these notes assume that you have made the following global definitions in CASA:
# In CASA
msdir='./'
project='c0xxx'
msfile=msdir+project+'.ms'
# In CASA
clean(vis=msfile,imagename='clean3pb_07dec',spw='1,2',field='3~51',
phasecenter='J2000 20h35m35.32 60d10m01.00',
cell=2.,imsize=[400,400],
mode='velocity',start='-103.00km/s',width='5.08km/s',nchan=29,
interpolation='linear',psfmode='clark',
imagermode='mosaic',ftmachine='mosaic',
scaletype='SAULT',restfreq='115.2712GHz',interactive=F,
minpb=0.1,pbcor=True,
niter=1000,threshold='340mJy',mosweight=False,
weighting='natural')