Deconvolve Image: Difference between revisions
From CASA Guides
Jump to navigationJump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
[[Simulating Observations in CASA | ↵ '''Simulating Observations in CASA''']] | |||
* <tt>simdata</tt> just calls <tt>[[clean]]</tt>, so you should refer to help clean for more information. | * <tt>simdata</tt> just calls <tt>[[clean]]</tt>, so you should refer to help clean for more information. | ||
* '''psfmode''' serves as a switch. If you want to just calculate visibilities and not deconvolve, set '''psfmode'''="none" | * '''psfmode''' serves as a switch. If you want to just calculate visibilities and not deconvolve, set '''psfmode'''="none" |
Revision as of 20:35, 4 December 2009
↵ Simulating Observations in CASA
- simdata just calls clean, so you should refer to help clean for more information.
- psfmode serves as a switch. If you want to just calculate visibilities and not deconvolve, set psfmode="none"
- leave psfmode as is and set niter=0 if you want to make a dirty image but not clean.
- threshold, weighting, robust, uvtaper, stokes, niter control the cleaning.
- simdata's default clean parameters are not particularly aggressive and almost certainly not optimal for your application. I recommend that you run simdata and then clean the measurement set in various ways to determine the best results.