VLA Data Combination-W49A-CASA6.2.0: Difference between revisions
Line 261: | Line 261: | ||
[https://casadocs.readthedocs.io/en/v6.2.0/api/tt/casatasks.manipulation.statwt.html statwt] will bring all the weights of all observations on the same scale. The task recalculates the visibility weights based on the inverse of their rms. Task [https://casadocs.readthedocs.io/en/v6.2.0/api/tt/casatasks.manipulation.statwt.html statwt] is part of the [https://go.nrao.edu/vla-pipe VLA pipeline], so the pipelined data may already have recalculated weights and this step can be skipped. It does not hurt though, to re-run [https://casadocs.readthedocs.io/en/v6.2.0/api/tt/casatasks.manipulation.statwt.html statwt]. | [https://casadocs.readthedocs.io/en/v6.2.0/api/tt/casatasks.manipulation.statwt.html statwt] will bring all the weights of all observations on the same scale. The task recalculates the visibility weights based on the inverse of their rms. Task [https://casadocs.readthedocs.io/en/v6.2.0/api/tt/casatasks.manipulation.statwt.html statwt] is part of the [https://go.nrao.edu/vla-pipe VLA pipeline], so the pipelined data may already have recalculated weights and this step can be skipped. It does not hurt though, to re-run [https://casadocs.readthedocs.io/en/v6.2.0/api/tt/casatasks.manipulation.statwt.html statwt]. | ||
For more information on weights, see [https://casadocs.readthedocs.io/en/stable/notebooks/data_weights.html definition of data weights] | For more information on weights, see [https://casadocs.readthedocs.io/en/stable/notebooks/data_weights.html definition of data weights]. | ||
Task [https://casadocs.readthedocs.io/en/v6.2.0/api/tt/casatasks.manipulation.statwt.html statwt] will be executed on each MS. The default setting calculates the weight based on the rms of each scan and spectral window. This setting works quite well for continuum observations. We would like to note though that for spectral line data the ''fitspw'' parameter should be set to exclude the line from the calculations. Otherwise, strong lines will be down-weighted. | Task [https://casadocs.readthedocs.io/en/v6.2.0/api/tt/casatasks.manipulation.statwt.html statwt] will be executed on each MS. The default setting calculates the weight based on the rms of each scan and spectral window. This setting works quite well for continuum observations. We would like to note though that for spectral line data the ''fitspw'' parameter should be set to exclude the line from the calculations. Otherwise, strong lines will be down-weighted. |
Revision as of 20:50, 10 September 2021
This tutorial was created and tested using CASA 6.2.0
Introduction
A perfect image requires measurement of all spatial scales, which is equivalent to filling in the complete uv plane. Unfortunately, this can never be achieved with an aperture synthesis interferometer, although a large number of baselines, long integration times, and multi-frequency-synthesis are all good approaches to increase the uv-coverage. One method to obtain more baselines is to observe in different array configurations and to combine the data afterwards. Deconvolution algorithms are then given good starting conditions to interpolate across the gaps in the uv-plane to achieve an image that combines the surface brightness sensitivity of the compact baselines with the spatial resolution of the extended baselines.
The VLA can be configured into four principal array configurations, A, B, C, and D; A is the most extended and D is the most compact configuration. Consequently, A configuration data exhibit the highest spatial resolution whereas D configuration delivers the best surface brightness sensitivity and also images the largest scales of the sky brightness distribution.
In this tutorial, we will combine data from all four VLA configurations (A, B, C, and D) that were observed in X-band continuum toward W49A, a massive star forming region in the Milky Way.
Typical Observing Times
When an object is being observed by the VLA in different array configurations, on-source integration times are ideally matched to reach a common surface brightness sensitivity for all scales. Adjacent VLA configurations result in synthesized beams that differ in linear size by approximately a factor of 3. The beam areas therefore change by factors of ~10 and the more extended configuration would ideally need to have 10 times more integration time than the next compact one. This, however, is frequently not very practical and it turns out that integration times that differ by factors of ~3 deliver data that can be satisfactorily combined. This combination matches the sensitivity of overlapping VLA visibilities when the data are convolved to the same scales.
Although overlapping uv-coverages are essential for the best imaging, it is possible to combine non-overlapping data if one understands that some spacings are not present and that the adjustment of the individual datasets is somewhat subjective. Weighting will be primarily achieved during imaging by the Briggs scheme that allows one to adjust imaging weights between the natural (weighting by the number of visibilities that are gridded in each cell) and uniform (weighting by the cells themselves) extremes.
Additionally, each visibility exhibits weights that should only depend on correlator integration time, bandwidth, and system temperature (Tsys). Note that the VLA does not apply Tsys in the online system. Visibility weights between different observations will therefore need to be adjusted, as described below, before they can be combined.
The Data
We will be combining four different datasets, X-band A, B, C, and D configuration data. The data were all calibrated and the science target split out.
The calibrated measurement sets can be downloaded here: https://casa.nrao.edu/Data/EVLA/combination/VLA-combination-W49A.tar.gz (3.0G)
As a first step download the file above, then untar:
# In a Terminal tar -xzvf VLA-combination-W49A.tar.gz
This will unpack four MeasurementSets (MSs), one for each array configuration:
A-W49A.ms B-W49A.ms C-W49A.ms D-W49A.ms
Initial Imaging
We will inspect the data and create separate images to better understand the image parameters such as on-source integration time, resolution, and rms.
Start CASA:
# In a Terminal casa
As a first step, let's have a look at the 'listobs' output for the different MSs. For example, the A-configuration MS has the following structure:
# In CASA
listobs(vis='A-W49A.ms')
########################################## ##### Begin Task: listobs ##### listobs( vis='A-W49A.ms', selectdata=True, spw='', field='', antenna='', uvrange='', timerange='', correlation='', scan='', intent='', feed='', array='', observation='', verbose=True, listfile='', listunfl=False, cachesize=50.0, overwrite=False ) ================================================================================ MeasurementSet Name: /lustre/aoc/sciops/jott/casa/combination-2021/data/vis-small3/A-W49A.ms MS Version 2 ================================================================================ Observer: Dr. Chris De Pree Project: uid://evla/pdb/30105074 Observation: EVLA Computing scan and subscan properties... Data records: 764478 Total elapsed time = 8973 seconds Observed from 24-Jun-2015/07:32:30.0 to 24-Jun-2015/10:02:03.0 (UTC) ObservationID = 0 ArrayID = 0 Date Timerange (UTC) Scan FldId FieldName nRows SpwIds Average Interval(s) ScanIntent 24-Jun-2015/07:32:30.0 - 07:42:24.0 4 0 W49A 69498 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 07:42:27.0 - 07:47:24.0 5 0 W49A 34749 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 07:49:27.0 - 07:59:21.0 7 0 W49A 69498 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 07:59:24.0 - 08:04:21.0 8 0 W49A 34749 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 08:06:24.0 - 08:16:18.0 10 0 W49A 69498 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 08:16:21.0 - 08:21:18.0 11 0 W49A 34749 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 08:23:21.0 - 08:33:18.0 13 0 W49A 69849 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 08:33:21.0 - 08:38:15.0 14 0 W49A 34398 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 08:40:18.0 - 08:50:15.0 16 0 W49A 69849 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 08:50:18.0 - 08:55:12.0 17 0 W49A 34398 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 08:57:15.0 - 09:07:12.0 19 0 W49A 69849 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 09:07:15.0 - 09:12:09.0 20 0 W49A 34398 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 09:40:09.0 - 09:50:03.0 25 0 W49A 69498 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 09:50:06.0 - 09:55:03.0 26 0 W49A 34749 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] 09:57:06.0 - 10:02:03.0 28 0 W49A 34749 [0] [3] [OBSERVE_TARGET#UNSPECIFIED] (nRows = Total number of rows per scan) Fields: 1 ID Code Name RA Decl Epoch SrcId nRows 0 NONE W49A 19:10:12.930999 +09.06.11.88200 J2000 0 764478 Spectral Windows: (1 unique spectral windows and 1 unique polarization setups) SpwID Name #Chans Frame Ch0(MHz) ChanWid(kHz) TotBW(kHz) CtrFreq(MHz) BBC Num Corrs 0 EVLA_X#B0D0#11 64 TOPO 8372.479 2000.000 128000.0 8435.4793 15 RR LL Sources: 1 ID Name SpwId RestFreq(MHz) SysVel(km/s) 0 W49A 0 9816.865 8 Antennas: 27: ID Name Station Diam. Long. Lat. Offset from array center (m) ITRF Geocentric coordinates (m) East North Elevation x y z 0 ea01 N64 25.0 m -107.37.58.7 +34.02.20.5 -1382.3871 15410.1384 -40.6410 -1599855.687000 -5033332.368600 3567636.613800 1 ea02 N16 25.0 m -107.37.10.9 +33.54.48.0 -155.8524 1426.6393 -9.3842 -1601061.957600 -5041175.881400 3556058.033100 2 ea03 W48 25.0 m -107.42.44.3 +33.50.52.1 -8707.9476 -5861.7878 15.5283 -1610451.932800 -5042471.123800 3550021.055800 3 ea04 E40 25.0 m -107.32.35.4 +33.52.16.9 6908.8199 -3240.7429 39.0197 -1595124.937100 -5045829.476200 3552210.683600 4 ea05 E72 25.0 m -107.24.42.3 +33.49.18.0 19041.8648 -8769.1806 4.7639 -1584460.883200 -5052385.614800 3547600.041100 5 ea06 N40 25.0 m -107.37.29.5 +33.57.44.4 -633.6056 6878.6057 -20.7877 -1600592.749000 -5038121.341300 3560574.846200 6 ea07 N72 25.0 m -107.38.10.5 +34.04.12.2 -1685.6797 18861.8360 -43.4978 -1599557.928700 -5031396.353400 3570494.743400 7 ea08 E64 25.0 m -107.27.00.1 +33.50.06.7 15507.6019 -7263.7123 67.2037 -1587600.192200 -5050575.870700 3548885.413900 8 ea09 W08 25.0 m -107.37.21.6 +33.53.53.0 -432.1156 -272.1458 -1.4994 -1601614.091200 -5042001.656900 3554652.514300 9 ea10 E32 25.0 m -107.34.01.5 +33.52.50.3 4701.6612 -2209.7048 25.2200 -1597053.118400 -5044604.692200 3553059.011100 10 ea11 W24 25.0 m -107.38.49.0 +33.53.04.0 -2673.3543 -1784.5861 10.4723 -1604008.747100 -5042135.805100 3553403.716300 11 ea12 N32 25.0 m -107.37.22.0 +33.56.33.6 -441.7251 4689.9820 -16.9255 -1600781.044100 -5039347.437000 3558761.543300 12 ea13 W16 25.0 m -107.37.57.4 +33.53.33.0 -1348.7131 -890.6107 1.2990 -1602592.853500 -5042054.989100 3554140.713000 13 ea14 E08 25.0 m -107.36.48.9 +33.53.55.1 407.8280 -206.0296 -3.2233 -1600801.931400 -5042219.381700 3554706.431200 14 ea15 E24 25.0 m -107.35.13.4 +33.53.18.1 2858.1759 -1349.1337 13.7125 -1598663.094300 -5043581.381100 3553767.012000 15 ea16 W64 25.0 m -107.46.20.1 +33.48.50.9 -14240.7524 -9606.2900 17.0885 -1616361.575500 -5042770.516600 3546911.419900 16 ea17 N24 25.0 m -107.37.16.1 +33.55.37.7 -290.3645 2961.8847 -12.2406 -1600930.072900 -5040316.384900 3557330.407200 17 ea18 W72 25.0 m -107.48.24.0 +33.47.41.2 -17419.4641 -11760.2694 14.9442 -1619757.299900 -5042937.656400 3545120.392300 18 ea19 W40 25.0 m -107.41.13.5 +33.51.43.1 -6377.9723 -4286.7839 8.2107 -1607962.451800 -5042338.204100 3551324.945500 19 ea20 N48 25.0 m -107.37.38.1 +33.59.06.2 -855.2671 9405.9613 -25.9164 -1600374.881000 -5036704.217500 3562667.893900 20 ea21 E56 25.0 m -107.29.04.1 +33.50.54.9 12327.6481 -5774.7445 42.6332 -1590380.599000 -5048810.261300 3550108.444300 21 ea23 E16 25.0 m -107.36.09.8 +33.53.40.0 1410.0345 -673.4704 -0.7961 -1599926.106100 -5042772.964400 3554319.787600 22 ea24 W32 25.0 m -107.39.54.8 +33.52.27.2 -4359.4410 -2923.1315 11.7693 -1605808.637100 23 ea25 W56 25.0 m -107.44.26.7 +33.49.54.6 -11333.1991 -7637.6832 15.3636 -1613255.391400 -5042613.097800 3548545.906000 24 ea26 E48 25.0 m -107.30.56.1 +33.51.38.4 9456.6036 -4431.6334 37.9266 -1592894.077600 -5047229.118200 3551221.221000 25 ea27 N08 25.0 m -107.37.07.5 +33.54.15.8 -68.9101 433.1984 -5.0732 -1601147.939700 -5041733.820400 3555235.956600 26 ea28 N56 25.0 m -107.37.47.9 +34.00.38.4 -1105.2275 12254.3062 -34.2445 -1600128.402500 -5035104.139200 3565024.670400 Result listobs: True Task listobs complete. Start time: 2021-09-10 10:01:51.648534 End time: 2021-09-10 10:01:51.932094 ##### End Task: listobs ##### ##########################################
The data were prepared for this tutorial to contain only one source, W49A, calibrated through the VLA pipeline (although, for the sake of this tutorial, no statwt task has been run, see below). To reduce the size of the files, the MS only contains one spectral window, binned into 64 2MHz channels around 8.4GHz (X-band). We also extracted the calibrated data, discarding the raw data and any model, such that the MS now only contains visibilities in the DATA column. The on-source integration time amounts to about 2.5h. Inspection of the other array configuration files show almost identical setups. Although the integration times between the different array configurations do not follow the 1:3:9:27 ratios that we discussed in the previous section, we can still combine the data without any problem. In the end, having a higher signal to noise ratio on the shorter baselines can only improve the overall combined image.
To better understand the data, let's check the uv-coverage of each of the four datasets. For faster plotting, we only plot channel 32 near the center of each spectral window. All plots are on the same scale:
# In CASA
# A-config:
plotms(vis='A-W49A.ms',xaxis='Uwave',yaxis='Vwave',spw='0:32',plotrange=[-1000000,1000000,-1000000,1000000])
# B-config
plotms(vis='B-W49A.ms',xaxis='Uwave',yaxis='Vwave',spw='0:32',plotrange=[-1000000,1000000,-1000000,1000000])
# C-config:
plotms(vis='C-W49A.ms',xaxis='Uwave',yaxis='Vwave',spw='0:32',plotrange=[-1000000,1000000,-1000000,1000000])
# D-config:
plotms(vis='D-W49A.ms',xaxis='Uwave',yaxis='Vwave',spw='0:32',plotrange=[-1000000,1000000,-1000000,1000000])
The uv-coverage plots are shown in Fig. 1a-d using a common scale. The longest baseline in each array differs by about a factor of 3, as expected, between the VLA A, B, C, and D configurations.
The next step is to determine the image quality, the synthesized beam, and the rms of each image. The images do not have to be perfectly deconvolved as we only would like to see how the combination will improve over the individual arrays.
To keep things simple, we will use common cell sizes of 0.05 arcsec, which samples well the A-configuration beam and oversamples the more compact configurations. We create images of 1280 pixels on each side, and we will tclean 1000 iterations (see the VLA CASA imaging guide for more sophisticated imaging parameter choices). We move the center of the image to the region with the main emission to avoid having to image a very large field of view:
# In CASA
# A-config:
tclean(vis='A-W49A.ms',imagename='Aonly',cell='0.05arcsec',imsize=[1280,1280],weighting='briggs',
robust=0,specmode='mfs',phasecenter='J2000 19:10:14 +09.06.13.7')
# B-config:
tclean(vis='B-W49A.ms',imagename='Bonly',cell='0.05arcsec',imsize=[1280,1280],weighting='briggs',
robust=0,specmode='mfs',phasecenter='J2000 19:10:14 +09.06.13.7')
# C-config:
tclean(vis='C-W49A.ms',imagename='Conly',cell='0.05arcsec',imsize=[1280,1280],weighting='briggs',
robust=0,specmode='mfs',phasecenter='J2000 19:10:14 +09.06.13.7')
# D-config:
tclean(vis='D-W49A.ms',imagename='Donly',cell='0.05arcsec',imsize=[1280,1280],weighting='briggs',
robust=0,specmode='mfs',phasecenter='J2000 19:10:14 +09.06.13.7')
The clean images, shown in Fig. 2a-d, give a first impression of the data. Note that when combining the images, we will improve on the uv-coverage and will therefore not only combine high resolution with high surface brightness sensitivity on large scales, but also expect a higher image fidelity, i.e. fewer artifacts due to better deconvolution. In particular, the ripples in the extended configuration data are the typical 'missing short spacing' bowls, that the more compact configurations will fill in to improve the image quality.
The basic parameters of the individual images can be checked through imhead and the beam sizes are 0.19"x0.19" for A, 0.71"x0.66" for B, 2.20"x2.04" for C and 8.44"x6.36" for D-configuration. This reflects again the factor of three in resolution between the different arrays.
Check and Adjust the Visibility Weights
VLA visibility weights are currently based only on channel width and correlator integration time. In the future, the VLA may use the switched power measurements to derive absolute calibrated weights. At the moment, however, the VLA weights need to be taken as being relative to each other. The relative sensitivity within an observation is measured by the gain, so weights of single, continuous observations are self-consistent. It is important to adjust the weights between separate observations as they will potentially be on different scales.
Let's have a look at the weights of the different datasets. We will plot the weights as a function of uv-distance in a single central channel for improved plotting time:
# In CASA
# A-config:
plotms(vis='A-W49A.ms',spw='0:32',xaxis='uvwave',yaxis='wt',coloraxis='antenna1')
# In CASA
# B-config
plotms(vis='B-W49A.ms',spw='0:32',xaxis='uvwave',yaxis='wt',coloraxis='antenna1')
# In CASA
# C-config:
plotms(vis='C-W49A.ms',spw='0:32',xaxis='uvwave',yaxis='wt',coloraxis='antenna1')
# In CASA
# D-config:
plotms(vis='D-W49A.ms',spw='0:32',xaxis='uvwave',yaxis='wt',coloraxis='antenna1')
Fig. 3a-d shows the weights and they are as described above.
The next step is to bring the weights on the same relative scale.
There are currently a number of options to do so.
1) Calculate the weights based on the rms of the visibilities themselves, using the statwt task.
2) Reset the weights with initweights to reflect the channel width and correlator integration time ([math]\displaystyle{ WEIGHT=2 \Delta \nu \Delta t }[/math], see the document on Data Weights in CASAdocs).
3) Calculate the weights based on the rms of the cross-polarization products (currently not supported in statwt).
We recommend to reset the weights when there are strong sources present in the data as they will change the rms of the visibilities and the rms will not be representative of the noise anymore. Without strong sources, statwt should deliver better results. The third option may work for both cases, but requires full polarization observations and calibrations. For this guide we will follow the statwt path as an example. But the user should be aware of the different options for optimized imaging.
Calculating the weights based on the rms
statwt will bring all the weights of all observations on the same scale. The task recalculates the visibility weights based on the inverse of their rms. Task statwt is part of the VLA pipeline, so the pipelined data may already have recalculated weights and this step can be skipped. It does not hurt though, to re-run statwt. For more information on weights, see definition of data weights.
Task statwt will be executed on each MS. The default setting calculates the weight based on the rms of each scan and spectral window. This setting works quite well for continuum observations. We would like to note though that for spectral line data the fitspw parameter should be set to exclude the line from the calculations. Otherwise, strong lines will be down-weighted.
Now, we execute statwt. Since the DATA column is our calibrated data (see above; in a general case it would be the CORRECTED_DATA column), we calculate the rms based on the values in that column:
# In CASA
# A-config:
statwt(vis='A-W49A.ms',datacolumn='data')
# In CASA
# B-config
statwt(vis='B-W49A.ms',datacolumn='data')
# In CASA
# C-config:
statwt(vis='C-W49A.ms',datacolumn='data')
# In CASA
# D-config:
statwt(vis='D-W49A.ms',datacolumn='data')
Let's have a look at the weight values again to see if statwt has adjusted the weights properly:
# In CASA
# A-config:
plotms(vis='A-W49A.ms',spw='0:32',xaxis='uvwave',yaxis='wt',coloraxis='antenna1')
# In CASA
# B-config
plotms(vis='B-W49A.ms',spw='0:32',xaxis='uvwave',yaxis='wt',coloraxis='antenna1')
# In CASA
# C-config:
plotms(vis='C-W49A.ms',spw='0:32',xaxis='uvwave',yaxis='wt',coloraxis='antenna1')
# In CASA
# C-config:
plotms(vis='D-W49A.ms',spw='0:32',xaxis='uvwave',yaxis='wt',coloraxis='antenna1')
In Fig. 4a-d we plot the new, recalculated weights for the three configurations. The absolute scaling has indeed changed. and is now in units of 1/Jy^2.
Combining and Imaging All Data
We will now create a combined image of all three re-weighted datasets.
First, let's check the new uv-coverage. We concatenate the data with concat (alternatively, one can use virtualconcat, a task that can also concatenate multi-MSs):
# In CASA
concat(vis=['A-W49A.ms','B-W49A.ms','C-W49A.ms','D-W49A'],concatvis='ABCD-W49A.ms')
Now let's plot the uv-coverage of the combined MSs. Since the spws have been renumbered, we plot the central channel of each sub-configuration with the spw='*:32' keyword:
# In CASA
plotms(vis='ABCD-W49A.ms',xaxis='Uwave',yaxis='Vwave',spw='*:32')
Fig. 5 shows the combined uv-coverage, which extends to A-configuration baselines but with a much higher density at the intermediate and shorter baselines contributed from B and C configurations.
Although concat merges all three MSs into a single one, it is actually not a required step before imaging. Task tclean will take care of the combination when all datasets are specified as a list. By default, tclean will image the data in the CORRECTED columns, i.e. it will use the portion of the MS which exhibits the data with the subtracted Sgr A* point source (if CORRECTED is not present, it will image the visibilities stored in the DATA column). Tclean will also perform the spectral regridding of all datasets on the fly, in particular in mode="velocity" or mode="frequency". There's no need to run cvel/cvel2 (or mstransform) to Doppler correct the MSs beforehand.
We will now create a combined image in tclean. The threshold parameter was derived by a previous run of tclean on the combined MS for which we determined the rough rms noise. For our threshold, we will use the rms noise multiplied by a factor of ~2.5.
Image the data with recalculated weights:
# In CASA
tclean(vis=['ABCD-W49A.ms'], imagename='W49A_combinedABCD',specmode='mfs',cell='0.05arcsec',imsize=[1280,1280],
niter=10000, weighting='briggs',robust=0, phasecenter='J2000 19:10:14 +09.06.13.7',threshold='2mJy')
The combined beam is now 0.26"x0.24". The image (Fig. 6) can still be improved upon. For simplicity, we did not use any interactive cleaning in the above, but we highly recommend it for producing the final images. Improvements can also be obtained by adjusting the image weights via the Briggs robust parameter, adding a taper, or weighting the different datasets against each other using visweightscale in concat. Wide-band imaging and multi-scale imaging will also lead to better results. We refer to the VLA CASA Imaging Guide for more details and examples.
Tips for Selfcal
If the source has a bright nucleus or, more generally, a bright unresolved emission, start with the A array data, selfcal, then add B array, selfcal again, and so on. This procedure starts with a high model flux that is increased further. If the source is mostly diffuse, then there is not much signal in the A array data, so start with the D array, selfcal, then add C array, selfcal, and so on. Each selfcal step should be phase only first with maybe two or more iterations. At the end of each selfcal step, a phase+amplitude selfcal can be attempted, before merging in the next array configuration data. After each merge the selfcal steps can be repeated.
Last checked on CASA Version 6.2.0.